background image

8

FILTER

HOSE 

CLAMP

HOSE
ADAPTER

 

HOSE 

CLAMP 

 
 

HOSE 
ADAPTER

 

1 1/2" OR 1 1/4" 
FLEX HOSE

  

1 1/2" 

X

  1 1/2" 

X

 1 1/4"

HOSE ADAPTER

HOSE 
CLAMP

PUMP

CHECK

VALVE

TO 

POOL 

 
 

TOOLS NEEDED              

Screwdriver

Pipe Wrench

MATERIALS NEEDED      

Pipe Thread Tape 
or Sealant

Two hose adapters
1½” X 1½” X 1¼”

Two Sections of 1½” 
or 1¼” Flex Hose (one 
provided with filter) 

Two 
Hose 
Clamps

RECOMMENDED               

4-8 psi Back Pressure

To avoid over or under 
chlorination, replace eyeball 
fittings in the return jets to a 
smaller or larger size to adjust 
back pressure. For best results 
use King Technology’s pressure 
gauge, order Part No.  
01-22-4000.

Apply pipe thread tape or 
sealant to the threaded end of 
both hose adapters.

1.

Installation with Flex Hose Only 

Screw adapters into each end 
of FROG Leap Infuzer. Hand 
tighten. Finish tightening by 
turning 1 to 2 revolutions with 
pipe wrench. 

DO NOT OVER 

TIGHTEN.

2.

Attach the filter section of flex 
hose to one hose adapter and 
the return section of flex hose 
to the other hose adapter 
with clamps and tighten with 
screwdriver. Bi-flow valve 
design allows water flow 
installation in either direction.

3.

To prevent damage to heaters or filters, install a 

corrosion resistant check valve

 which will reduce 

the back flow of chlorine gas when the system is 
turned off.

 

4.

For better stability, FROG 
Leap Infuzer may be 
mounted on a treated 

wood base using 

Phillips 

pan head screws, 

one 

in front and two in back. 
If you have questions 
about stability, please 
contact your dealer or King 
Technology.

5.

The FROG Leap Infuzer should always be installed between the filter and pool (or between heater and 
pool if applicable). 

Never install 

FROG Leap

 Infuzer before the heater or damage to the heater could 

occur.

TO POOL

 

PUMP

FILTER

HOSE 

CLAMP

HOSE

ADAPTERS

 

HOSE 

CLAMP

1 1/2" OR 1 1/4" 

     FLEX HOSE

 

CHECK

VALVE

Sand Filter

DE and Cartridge Filter

Содержание Leap 7800

Страница 1: ...Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with prefilled pacs for no mess no guess and no stress To minimize the risk of serious injury death or...

Страница 2: ...0 11 Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Pool Wake Up 16 Using FROG Leap All...

Страница 3: ...Anti Bac Mineral Pac Part No 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap All Out Part...

Страница 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended t...

Страница 5: ...OG Leap Torpedo Pacs FROG Leap Anti Bac Mineral Pacs FROG Leap Pool Wake Up Pool Hibernation which includes FROG Leap Reveille FROG Leap Depth Charge and FROG Leap All Out in the FROG Leap Infuzer Nev...

Страница 6: ...OOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve o...

Страница 7: ...ipe thread tape or sealant to each threaded end of nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of h...

Страница 8: ...tions with pipe wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tighten with screw...

Страница 9: ...b 3 Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the thre...

Страница 10: ...e adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as ir...

Страница 11: ...low 80 ppm Important Keep cap on tight between uses Store at room temperature www KingTechnology com Patent 6 030 842 Made in USA 553101443N Read v w IDEAL USE BY DATE ON BOTTLE USE ANTES FECHA SmartC...

Страница 12: ...ap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap All Out for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days inser...

Страница 13: ...RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24...

Страница 14: ...maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopenexcept whenopeningorservicingtheunit DANGER Never ad...

Страница 15: ...h fin inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue oper...

Страница 16: ...p 1 2 3 4 FROG Leap Depth Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard in tr...

Страница 17: ...in FROG Leap Infuzer to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap All Out...

Страница 18: ...ROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlo...

Страница 19: ...in If FROG Leap Torpedo Pac still contains chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust...

Страница 20: ...r if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for...

Страница 21: ...ipple Kit 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1426 Cap w O Ring 2 01 22 1922 Cap O Ring 4 01 22 9485 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial...

Страница 22: ...al until it locks into place Lubricate O ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRIC...

Страница 23: ...f the chemicals used in the product or their characteristics 3 Any express warranty not provided for herein and any remedy for breach of warranty or breach of contract which but for this provision mig...

Страница 24: ...g Technology Inc FROG FROG Leap Torpedo Pac FROG Leap FROG Leap Pool Wake Up Pool Hibernation FROG Leap Anti Bac Mineral Pac Fresh Mineral Water 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproduc...

Отзывы: