General Notes

These instructions contain information for the safe and proper 
operation of this Infuzer. Observe the following principles:
  • Ensure that everyone using this Infuzer follows the  

 

    instructions and safety precautions.
  • Keep the instructions nearby and available for reference
    throughout the service life of this Infuzer.

Signal Word

 

Meaning

DANGER

 

Indicates an imminently hazardous situation which, if not avoided, will result in death, serious injury 

or major property damage.

WARNING 

Indicates a hazardous situation which, if not avoided, could result in serious injury, death, or major 

property damage. 

NOTICE

NOTICE

 

Indicates special instructions that are important but not related to physical injury hazards.

Explanation of the safety pictographs

The following pictographs illustrate the type of hazard.

Pictograph

Type of Danger

Safety Alert/General Hazard

Explosion Risk

Hazardous Pressure

Flammable Fire Hazard

Identification of warnings

Warnings are intended to help you recognize risks and avoid 
death, injury or property damage. This is how warnings are identified:

     

Signal Word

Pictographs

Description of danger.

Consequences if ignored.

 a

 The arrow signals a safety precaution to be taken to

          eliminate or reduce the risk.

These instructions do not provide for every possible contingency 
that might be encountered in connection with installation, opera-
tion or maintenance of this equipment. Should further informa-
tion be desired or should particular issues arise which are not 
covered sufficiently in this manual, contact King Technology at 
800-222-0169.

Explanation of the signal words

Signal words, which depict the probability and severity of harm, are used in these instructions. They are defined as follows:

Notes and Safety Information

Содержание Leap 7800

Страница 1: ...Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with prefilled pacs for no mess no guess and no stress To minimize the risk of serious injury death or...

Страница 2: ...0 11 Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Pool Wake Up 16 Using FROG Leap All...

Страница 3: ...Anti Bac Mineral Pac Part No 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap All Out Part...

Страница 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended t...

Страница 5: ...OG Leap Torpedo Pacs FROG Leap Anti Bac Mineral Pacs FROG Leap Pool Wake Up Pool Hibernation which includes FROG Leap Reveille FROG Leap Depth Charge and FROG Leap All Out in the FROG Leap Infuzer Nev...

Страница 6: ...OOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve o...

Страница 7: ...ipe thread tape or sealant to each threaded end of nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of h...

Страница 8: ...tions with pipe wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tighten with screw...

Страница 9: ...b 3 Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the thre...

Страница 10: ...e adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as ir...

Страница 11: ...low 80 ppm Important Keep cap on tight between uses Store at room temperature www KingTechnology com Patent 6 030 842 Made in USA 553101443N Read v w IDEAL USE BY DATE ON BOTTLE USE ANTES FECHA SmartC...

Страница 12: ...ap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap All Out for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days inser...

Страница 13: ...RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24...

Страница 14: ...maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopenexcept whenopeningorservicingtheunit DANGER Never ad...

Страница 15: ...h fin inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue oper...

Страница 16: ...p 1 2 3 4 FROG Leap Depth Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard in tr...

Страница 17: ...in FROG Leap Infuzer to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap All Out...

Страница 18: ...ROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlo...

Страница 19: ...in If FROG Leap Torpedo Pac still contains chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust...

Страница 20: ...r if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for...

Страница 21: ...ipple Kit 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1426 Cap w O Ring 2 01 22 1922 Cap O Ring 4 01 22 9485 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial...

Страница 22: ...al until it locks into place Lubricate O ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRIC...

Страница 23: ...f the chemicals used in the product or their characteristics 3 Any express warranty not provided for herein and any remedy for breach of warranty or breach of contract which but for this provision mig...

Страница 24: ...g Technology Inc FROG FROG Leap Torpedo Pac FROG Leap FROG Leap Pool Wake Up Pool Hibernation FROG Leap Anti Bac Mineral Pac Fresh Mineral Water 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproduc...

Отзывы: