falling of unit.
28.Always insert the filters securely.
Clean filter once every two weeks.
Operation without filters may cause
failure.
29.Do not place heavy object on the
power cord and take care so that
the cord is not compressed. There
is danger of fire or electric shock.
30.Do not place obstacles around air-
inlets or inside of air-outlet. It may
cause failure of appliance or
accident.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably
install the unit at one of these sites, please consult your local distributor
beforehand:
1. Site with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight
of the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the
indoor unit, as shown in the
following figure.
5. There should be at least 1 meter (3
feet) between the unit and radio
and television devices. It is ideal
that the unit be installed at the
center of the environment.
6. It must be far from fire, smoke or
flammable gases.
7. The indoor unit must be at least
2.3 meters (7.5 feet) from the
ground.
Choosing the Installation Site
More
than15cm
More
than 12cm
More than
200cm
More
than 12cm
07
08