1. Remove the electrical control board
cover from the outdoor unit by
loosening the screw.
2. Connect the connective cables to the
terminals as identified with their
respective matched numbers on the
terminal block of indoor and outdoor
units. The connective cable to power
supply shall be approved
polychloroprene sheathed flexible
cord, type designation 245 IEC
57(H07RN-F) or heavier cord.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water, from
a loop of the connective cable as
illustrated in the installation diagram
of indoor and outdoor units.
5. Insulate unused cords (conductors)
with PVC-tape.Process them so they
do not touch any electrical or metal
parts.
Connect the cable to the outdoor unit
Screw
Cover
40mm
40mm
10mm
10mm
< 18000 btu's CABLE (Cooling model)
> 18000 btu's btu's CABLE
(Heating and cooling model)
Cable code
< 18000 btu's CABLE
(Heating and cooling model)
40mm
10mm
40mm
10mm
"Cable D”
"Cable F”
"Cable E”
or
Cable code
Cable code
Cable code
23
24
9000 and 18000 Btu's
COOLING MODEL
24000 Btu's
HEATING AND COOLING MODE
30000 or 36000 Btu's
HEATING AND COOLING MODE
9000 and 18000 Btu's
HEATING AND COOLING MODEL
1 2(N) 3 4
1 2(N) 3 4
1 2(N) 3 4
1 2(N)
or
or
Terminal block of indoor unit
Terminal block of indoor unit
Terminal block of indoor unit
Terminal block of indoor unit
or
or
or
"Connector A"
"Connector A"
"Connector A"
"Connector A"
"Connector B"
"Connector B"
"Connector B"
To outdoor
unit
To outdoor
unit
To outdoor
unit
To outdoor
unit
To outdoor
unit
To outdoor
unit
To outdoor
unit
G
2(N)
or