1. Never fail to have an individual power circuit specifically for the air
conditioner. As for the method of wiring, be guided by the circuit diagram
posted on the inside of control cover.
2. The screw which fasten the wiring in the casing of electrical fittings are
liable to come loose from vibrations to which the unit is subjected during
the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
5. See to that the starting voltage is maintained at more than 90 percent of the
rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the power source
specification.
7. Always install an earth leakage circuit breaker in a wet or moist area.
8. The following would be caused by voltage drop. Vibration of a magnetic
switch, which will damage the contact point, fuse breaking, disturbance of
the normal function of the overload.
9. The means for disconnection from a power supply shall be incorporated in
the fixed wiring and have an air gap contact separation of at least 3mm in
each active (phase) conductors.
Caution
After the confirmation of the above conditions, prepare the wiring as follows:
Air purging
Air and moisture in the refrigerant system have undesirable effects as
indicated below:
1. Pressure in the system rises.
2. Operating current rises.
3. Cooling or heating efficiency
drops.
4. Moisture in the refrigerant circuit
may freeze and block capillary
tubing.
5. Water may lead to corrosion of
parts in the refrigeration system.
6. Therefore, the indoor unit and
tubing between the indoor and
outdoor unit must be leak tested
and evacuated to remove any
noncondensables and moisture
from the system.
25
26
9000 and 18000 Btu's
COOLING MODEL
24000 Btu's
HEATING AND COOLING MODEL
30000 or 36000 Btu's
HEATING AND COOLING MODEL
9000 and 18000 Btu's
HEATING AND COOLING MODEL
or
or
o
or
or
"Conector A"
"Conector A"
"Conector A"
"Conector C”
"Conector A"
"Conector B"
"Conector B"
"Conector B"
"Conector D”
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board
Wire connector of outdoor unit
Tablero terminal de la unidad externa
Wire connector of outdoor unit
Wire connector of outdoor unit
Wire connector of outdoor unit
1
2(N)
1 2(N)
4
1
3
2(N)
4
1
3
2(N)
1
3
4
2(N)
4
1
3
2(N)
1 2(N) S
N
L
1 2(N) S
N
L