43
Table 13-4
Information requirements for heat pump space heaters and heat pump combination heaters
Model (s):
KEM-60 DRS4
Air-to-water heat pump:
[yes]
Water-to-water heat pump:
[yes/no]
Brine-to-water heat pump:
[yes/no]
Low-temperature heat pump:
[yes/no]
Equipped with a supplementary heater:
[yes/no]
Heat pump combination heater:
[yes/no]
For low-temperature heat pumps, parameters shall be declared for low-temperature application. Otherwise, parameters shall be
declared for medium-temperature application. Parameters shall be declared for average climate conditions.
Item
Symbol
Value
Unit
Item
Symbol
Value Unit
Rated heat output
(3)
at Tdesignh =
-10 (-11) °C
Prated
=Pdesignh
36.55
kW
Seasonal space heating
energy efficiency
η
s
151.40
%
Seasonal coefficient of performance
SCOP
3.86
--
Active mode coef. of
performance
SCOP
on
--
--
Net seasonal coef. of
performance
SCOP
net
--
--
T
j
= -7°C
Pdh
32.33
kW
T
j
= -7°C
COPd
2.59
--
T
j
= +2°C
Pdh
20.64
kW
T
j
= +2°C
COPd
3.76
--
T
j
= +7°C
Pdh
12.89
kW
T
j
= +7°C
COPd
5.04
--
T
j
= +12°C
Pdh
14.18
kW
T
j
= +12°C
COPd
6.02
--
T
j
= bivalent temperature
Pdh
32.33
kW
T
j
= bivalent temperature
COPd
2.59
--
T
j
= operation limit temperature
Pdh
35.42
kW
T
j
=operation limit
temperature
COPd
2.28
--
For air-to-water heat pumps:
T
j
= – 15 °C (if TOL < – 20 °C)
Pdh
--
kW
For air-to-water heat pumps:
T
j
=–15°C (if TOL<–20°C)
COPd
--
--
Bivalent temperature (maximum
+2°C)
Tbiv
-10
°C
For air-to-water HP:
Operation limit temperature
(maximum-7°C)
TOL
-10
°C
Cycling interval capacity for heating
at T
j
= -7°C
Pcych
--
kW
Degradation coefficient
(4)
at T= -7°C
Cdh
--
--
Heating water operating limit
temperature
WTOL
--
°C
Cycling interval capacity for heating
at T
j
=+2°C
Pcych
--
kW
Degradation coefficient
(4)
at T= +2°C
Cdh
--
--
Cycling interval efficiency
at T
j
= +7°C
COPcyc
--
--
Cycling interval capacity for heating
at T
j
= +7°C
Pcych
--
kW
Cycling interval capacity for
heating at T
j
=+12°C
COPcyc
--
--
Degradation coefficient
(4)
at T
j
= +7°C
Cdh
--
--
Cycling interval efficiency
at T
j
= +7°C
COPcyc
--
--
Cycling interval capacity for heating
at T =+12°C
Pcych
--
kW
Degradation coefficient
(4)
at T
j
= +12°C
Cdh
--
--
Cycling interval capacity for
heating at T
j
=+12°C
COPcyc
--
--
Power consumption in modes other than active mode
Off mode
P
OFF
0.035
kW
Supplementary heater (to be declared even if not
provided in the unit)
Thermostat-off mode
P
TO
0.409
kW
Rated heat output (3)
Psup =sup
(Tj)
--
kW
Standby mode
P
SB
0.035
kW
Type of energy input
Crankcase heater mode
P
CK
0
kW
Outdoor heat exchanger
Other items
For air-to-water HP: Rated
air flow rate
Q
airsource
24000 m
3
/h
Capacity control
Fixed/Variable
Variable
For water-to-water: Rated
water flow rate
Q
watersource
x
m
3
/h
Sound power level, indoors
L
WA
x
dB (A)
Sound power level, outdoors
L
WA
86
dB (A) For brine-to-water: Rated
brine flow rate
Q
brinesource
x
m
3
/h
Contact details
Name and address of the manufacturer or its authorised representative
.
(1) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for
heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating
sup (Tj).
(2) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
16127100A05390 MD18IU-015AW(DZ-1)