STEP 6.
Cut the window seal gasket (C in parts list) to match the
window width and insert it between the window sashes as
shown in Figure 20. .
CIRCUIT PROTECTION
- If the air conditioner is circuit protected by a
fuse, use a "TIME DELAY" fuse or HACR type circuit breaker due to
momentary high current demand when your air conditioner is started.
Before operating your unit, verify the ampere rating of the time-delay
fuse or circuit breaker which protects your unit. The ampere rating of the
time-delay fuse or circuit breaker shall be 15 amps
Now that installation is complete, your unit is ready to operate! Simply
plug in the power cord and follow the operation steps outlined in this
manual or your QuickStart Guide.
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Unplug unit prior to performing any service.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Your Kühl Q unit will come with the power cord already installed and routed
to the left side of the unit.
For convenience and optimum appearance the direction of the power
cord can be changed from left to right by following the procedure below.
Select the exit location on the left or right based on proximity to the power
outlet.
(See Figure 22)
Figure 20
Plug in unit.
.
STEP 7.
Cord Routing Options
Replacement Installation Instructions
Your new Kühl Q chassis will fit in all previous Friedrich Q-size sleeves.
Replacement installation instructions are the same for both window and
thru-the-wall.
Inspect your existing Friedrich Q-size sleeve to ensure it is properly
installed and in good condition.
Remove the new Kühl Q chassis from the new sleeve (as outlines in
STEP 5.1 on page 17).and insert into previously installed sleeve. Obtain
assistance as needed.
Remove adhesive backing from supplied shell gasket (D in parts list) and
place along the bottom sill channel, centered, extending up the sides of
the shell. (see Figure 21).
Figure 21
Figure 22
SHELL GASKET (ITEM D).