background image

7

MOUNT THE COVER PLATE

AND THE INTAKE GRILLE

1. MOUNT THE COVER PLATE (RIGHT)

(1) Cut a pipe exit hole in the right plate. This is only when the pipe exits

from the right side. (This operation is not required when the protru-
sion is on the top or rear.)

(2) Join the cover plates (right) and mount with screws.

Cover plate (Right)

2. MOUNT THE COVER PLATE (LEFT)

Join the cover plates (left) and mount with screws.

3. MOUNT THE INTAKE GRILLE

(1) Cut the right side of the intake grille. This is only when the pipe exits

from the right side.

Cover plate (Left)

(2) Insert the hinges on the bottom of the intake grille into the holes in the

base assembly. Then mount the arms to the three areas on the top of
the intake grille.

Error

The OPERATION, TIMER and SWING lamps operate as follows (ta-
ble) according to the error contents.

Indoor unit circuit board error
Indoor unit room temperature sensor wire
opened
Indoor unit room temperature sensor wire
short circuited

Indoor unit piping sensor wire opened

Indoor unit piping sensor short circuited

Indoor unit fan error
Outdoor unit circuit board error
Miswiring between outdoor unit and
indoor unit
Outdoor unit discharge temperature
sensor error
Outdoor unit piping sensor error
Outdoor unit outdoor temperature sensor
error

 Error contents

Error display

 OPERATION

TIMER

 SWING

(RED)

(GREEN) (ORANGE)

2 times 

2 times 

3 times 

3 times 

6 times 

5 times

5 times

5 times 

                    3 times

4 times

: Fast flashing

: Slow flashing

— : Off

CHECK ITEMS

(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do not air flow direction louvers operate normally?
(4) Is the drain normal?
(5) Is there any abnormal noise and vibration during operation?

Do not operate the air conditioner in the test running state for a long
time.

For the operation method, refer to the operating manual and perform
operation check.

 Error contents

Error display

1. REMOTE CONTROL UNIT HOLDER

INSTALLATION

Install the remote control unit with a distance of 7 m (23 ft) between the
remote control unit and the photocell as the criteria. However, when
installing the remote control unit, check that it operates positively.

Install the remote control unit holder to a wall, pillar, etc. with the tap-
ping screw.

REMOTE CONTROL UNIT

INSTALLATION

1

 Set

Remote Control Unit
holder fixing

Remote Control
Unit mounting

2

 Push

Remote
control unit

Tapping
screw
(small)

Remote control
unit holder

2. SWITCHING REMOTE CONTROL UNIT SIGNAL

CODES

Air conditioner settings

8

Jumper wire

JM3

Connect

Disconnect

Connect

Disconnect

Remote control unit

signal code

A (Primary setting)

B

C

D

JM2

Connect

Connect

Disconnect

Disconnect

Confirm the setting of the remote control unit signal code and the printed
circuit board setting.
If these are not confirmed, the remote control unit cannot be used to
operate for the air conditioner.

 CAUTION

(1) Check that the indoor unit correctly receives the sig-

nal from the remote control unit, then install the remote
control unit holder.

(2) Select the remote control unit holder selection site by

paying careful attention to the following:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from
a stove, etc.

Содержание MS24Y3F

Страница 1: ...SONAL INJURY OR DEATH ONLY A QUALIFIED EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked H...

Страница 2: ...unit Floor console This air conditioner uses new refrigerant HFC R410A The basic installation work procedures are the same as conventional refrigerant models However pay careful attention to the foll...

Страница 3: ...installed on the top or right side When the directions are selected drill 80 mm 3 1 8 and 50 mm 2 or 150 mm 6 dia hole on the wall so that the hole is tilted downward to ward the outdoor for smooth w...

Страница 4: ...ened smoothly If the flare nut is forced to turn the threads will be damaged 2 Install the outdoor unit wall cap supplied with the optional installation set or procured at the site to the wall hole pi...

Страница 5: ...OPERATION lamp Red TIMER lamp Green SWING lamp Orange SWING lamp Orange Operation can be checked by lighting and flashing of the display section OPERATION and TIMER lamps Perform judgement in accordan...

Страница 6: ...the remote control unit normal 2 Does each lamp light normally 3 Do not air flow direction louvers operate normally 4 Is the drain normal 5 Is there any abnormal noise and vibration during operation D...

Страница 7: ...nges must be made to the settings if the unit is to be used as a wired type 3 Changing the settings for the electrical circuits Switch 4 SW4 on the printed circuit board inside the electric compo nent...

Страница 8: ...be operated at the same time using a single remote controller 1 Wiring method indoor unit to remote controller 3 AUTO RESTART When the air conditioner power was temporarily turned off by a power fail...