CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating
manual:

(1) Starting and stopping method, operation switching, temperature ad-

justment, timer, air flow switching, and other remote control unit op-
erations.

(2) Air filter removal and cleaning, and how to use the air louvers.
(3) Give the operating and installation manuals to the customer.
(4) If the signal code is changed, explain to the customer how it changed

(the system returns to signal code A when the batteries in the remote
control unit are replaced).

Remote control unit settings

(1) Press the START/STOP button and display only the clock.

(2) Press the MASTER CONTROL button continuously for more than five

seconds to display the current signal code.

(3) Change the signal code with the 

 button (

).

(4) Press the MASTER CONTROL button again to return to the clock

display and change the signal code.

JM1 (A)

JM2 (R1)

JM3 (R2)

WIRED REMOTE CONTROL
UNIT SETTING (OPTIONAL)

10

BEFORE INSTALL WIRED REMOTE CONTROL UNIT

The wired remote control unit is an option. It isn't
included in main body of air-conditioner.

When you use wired remote control unit, some func-
tions may not be used.

please use the recommended wired remote control
unit.

(Before installing, please read the FEATURES AND
FUNCTIONS section of OPERATING MANUAL to con-
firm the concerned contents.)

 CAUTION

(1) Before installing, be sure to disconnect all power

supply.

(2) Don't touch the heat exchanger.

(3) During installing or removing operation, be sure

not to have wire catched by parts or draw it
hard. Or it may result troubles to the air-condi-
tioner.

(4) Avoid place in direct sunlight.

(5) Select place that will not be affected by the heat

from a stove, etc.

(6) Insure the length of wire is not over the recom-

mended maximum length.

(7)  Before setting up the wired remote control unit,

please confirm whether air-conditioner can re-
ceive the signal.

REMO

TE

CONTR

OL

BLACK

WHITE

RED

REMO

T

E

CONTR

O

L

Use the tool to
remove the screw.

CLAMP

CONTROL BOX

CLAMP

CONTROL BOX

Terminal block

Terminal block

Remote control wire

Replace the screw with
the wired remote control
cable inserted.

When using the optional wired remote control, perform the wiring as shown
below.

Wireless remote control/wired remote control select switch

1

The electrical circuits for this were set for use as a wireless type at the
factory.

2

The following changes must be made to the settings if the unit is to be
used as a wired type.

3

Changing the settings for the electrical circuits.
Switch 4 (SW4) on the printed circuit board inside the electric compo-
nent box must be set as follows.

SW4

SW4

Wireless remote

control type

Wired remote

control type

SW4

Microcomputer

Printed circuit
board

 CAUTION

(1) When the optional wired remote control is used,

please refer to the wired remote control manual
supplied with the wired remote control.

(2) When the unit is set for the optional wired re-

mote control, the wireless remote control can-
not be used.

(3) When the unit is set for the optional wired re-

mote control, MANUAL/AUTO switch on the
indoor unit cannot be used.

(4) When the unit is set for the optional wired re-

mote control, the Display Timer lamp (Green)
on the indoor unit will no longer light.

(1) Stop the air conditioner operation.
(2) Press the master control button and the fan control button simultane-

ously for 2 seconds or more to start the test run.

(3) Press the start/stop button to stop the test run.

[SELF-DIAGNOSIS]

When the error indication “E:EE” is displayed, follow the following items to
perform the self-diagnosis. “E:EE” indicates an error has occurred.

Test run display

TEST RUN

SU MO TU WE TH FR SA

Unit number (usually 0)

Error code

REMOTE CONTROLLER DISPLAY

(1) Stop the air conditioner operation.

(2) Press the set temperature buttons 

 simultaneously for

5 seconds or more to start the self-diagnosis.
Refer to the following tables for the description of each error code.

(3) Press the set temperature buttons 

 simultaneously for

5 seconds or more to stop the self-diagnosis.

Ex. Self-diagnosis

Error code

Error contents

Communication error
(indoor unit

remote controller)

Communication error
(indoor unit 

 outdoor unit)

Room temperature sensor open

Room temperature sensor short-circuited

Indoor heat exchanger temperature sensor open

Indoor heat exchanger temperature sensor short-
circuited

Outdoor heat exchanger temperature sensor

Power source connection error

Float switch operated

Outdoor temperature sensor

Discharge pipe temperature sensor

Model abnormal

Indoor fan abnormal

Outdoor signal abnormal

Excessive outdoor pressure (permanent stop)

Compressor temperature sensor

Pressure switch error

IPM error

CT error

Active filter module (AFM) error

Compressor does not operate

Outdoor unit fan error

Communication error
(inverter

multicontroller)

2 way valve sensor error

Expansion valve error

Connection indoor unit error

00

01

02
03

04

05
06

08

09

0A

0c

11
12

13

14

15

16

17

18

19

1A

1b

1c

1d

1E

1F

Содержание MS24Y3F

Страница 1: ...SONAL INJURY OR DEATH ONLY A QUALIFIED EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked H...

Страница 2: ...unit Floor console This air conditioner uses new refrigerant HFC R410A The basic installation work procedures are the same as conventional refrigerant models However pay careful attention to the foll...

Страница 3: ...installed on the top or right side When the directions are selected drill 80 mm 3 1 8 and 50 mm 2 or 150 mm 6 dia hole on the wall so that the hole is tilted downward to ward the outdoor for smooth w...

Страница 4: ...ened smoothly If the flare nut is forced to turn the threads will be damaged 2 Install the outdoor unit wall cap supplied with the optional installation set or procured at the site to the wall hole pi...

Страница 5: ...OPERATION lamp Red TIMER lamp Green SWING lamp Orange SWING lamp Orange Operation can be checked by lighting and flashing of the display section OPERATION and TIMER lamps Perform judgement in accordan...

Страница 6: ...the remote control unit normal 2 Does each lamp light normally 3 Do not air flow direction louvers operate normally 4 Is the drain normal 5 Is there any abnormal noise and vibration during operation D...

Страница 7: ...nges must be made to the settings if the unit is to be used as a wired type 3 Changing the settings for the electrical circuits Switch 4 SW4 on the printed circuit board inside the electric compo nent...

Страница 8: ...be operated at the same time using a single remote controller 1 Wiring method indoor unit to remote controller 3 AUTO RESTART When the air conditioner power was temporarily turned off by a power fail...

Отзывы: