100 mm (4")

1

INSTALLATION PROCEDURE

Install the room air conditioner as follows:

PREPARING INDOOR UNIT

INSTALLATION

1. REMOVE THE INTAKE GRILLE

Open the intake grille and remove the three screws.

Remark: The main unit can be wired before the indoor unit is in-

stalled. Select the most appropriate installation order.

Machine screw

Tapping screw

Intake grille

Tapping screw

2

INDOOR UNIT INSTALLATION

A. FLOOR  CONSOLE TYPE

1. DRILLING FOR PIPING

Select piping and drain directions.
The piping and drain can be made in three directions as shown below.

The drain hose can be connected to either the left or right side.

Drain hose
(Right side)

Drain hose
(Left side)

When installing set to wall install the accessory wall bracket at the posi-
tion shown in figure, and mount the set to it.

Wall

Outdoor side

6 mm (1/4")

Indoor side

2. INSTALLING THE  DRAIN  HOSE

Select whether the drain hose will be connected to the left or right side.
Insert the drain hose into the drain pan, then secure the drain hose with a
nylon fastener.

Nylon fastener

Wrap the insulation (drain hose) around the drain hose connection.

Drain pan

Drain hose

Insulation (Drain hose)

Drain pan

Drain hose

Be sure to arrange the drain hose so that it is leveled lower than the drain
hose connecting port of the indoor unit.

 CAUTION

Do not install the unit so that the drain hose side is too
high. Height A should be less than 5 mm (3/16").

Arrange the drain
hose lower than
this portion.

Drain hose

B. UNDER CEILING TYPE

Using the installation template, drill holes for piping and anchor bolts (for
holes).

Drain hose

900 mm (35-7/16")

200 mm
(7-7/8" )

Drilling position
for piping

Installation
template

Drilling position
for anchor bolt

Ceiling

Wall

1. DRILLING FOR PIPING

Select piping and drain directions.

 CAUTION

Install the drain hose at the rear; it should not be installed
on the top or right side.

When the directions are selected, drill 80 mm (3-1/8") and 50 mm (2") or
150 mm (6") dia. hole on the wall so that the hole is tilted downward to-
ward the outdoor for smooth water flow.

Top

Rear (Install the
drain hose in this
direction.)

Right

Wall

6  mm (1/4")

Indoor side

Outdoor side

When the directions are selected, drill a 10 cm (4") dia. hole on the wall so
that the hole is tilted downward toward the outdoor for smooth water flow.
When the pipe is led out from the rear, make a hole in figure, at the posi-
tion shown.

2. DRILLING HOLES FOR ANCHOR BOLTS AND

INSTALLING THE ANCHOR BOLTS

With a concrete drill, drill four 12.7 mm (1/2") dia. holes.

60 to 70 mm

(2-3/8" to 2-3/4")

ø 12.7 mm (1/2")

3. INSTALLING BRACKETS

Install the brackets with nuts, washers and spring washers.

Insert the anchor bolts into the drilled holes, and drive the pins completely
into the anchor bolts with a hammer.

Apply the indoor unit to the brackets.

Spring
washer

Special nut

Bracket

Bracket (Left)

Bracket (Right)

4. INSTALLING INDOOR UNIT

Reset the hex bolts as shown in figure.

Hex bolt

Indoor unit

8 to 13 mm
(5/16" to 1/2")

Bolt

Bracket

Indoor unit

Now, securely tighten the hex bolts in both sides.

5. INSTALLING THE DRAIN HOSE

Select whether the drain hose will be connected to the left or right side.
Insert the drain hose into the drain pan, then secure the drain hose with a
nylon fastener.
Wrap the insulation (drain hose) around the drain hose connection.
Be sure to arrange the drain hose so that it is leveled lower than the drain
hose connecting port of the indoor unit.

Remove the hole cover.

Drain hose

Arrange the drain hose
lower than this portion.

Piping hole

VT wire
hole

Pass the drain hose
through here.

Base (Bottom)

Cut the grille

VT wire

Drain hose

Intake grille

50 cm (20")

24.5 cm
(9-5/8")

6.5 cm (2-1/2")

10 cm (4") hole

5 cm (2") hole

12.5 cm (5")

10 cm (4")

6.5 cm (2-1/2")

65.5 cm (26")

53 cm (21")

4.5 cm (1-3/4")

Wall bracket

Side of set

99 cm (39")

OK

NO

When drain hose is arranged backward.
Secure the drain hose with the VT wire.

Содержание MS24Y3F

Страница 1: ...SONAL INJURY OR DEATH ONLY A QUALIFIED EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked H...

Страница 2: ...unit Floor console This air conditioner uses new refrigerant HFC R410A The basic installation work procedures are the same as conventional refrigerant models However pay careful attention to the foll...

Страница 3: ...installed on the top or right side When the directions are selected drill 80 mm 3 1 8 and 50 mm 2 or 150 mm 6 dia hole on the wall so that the hole is tilted downward to ward the outdoor for smooth w...

Страница 4: ...ened smoothly If the flare nut is forced to turn the threads will be damaged 2 Install the outdoor unit wall cap supplied with the optional installation set or procured at the site to the wall hole pi...

Страница 5: ...OPERATION lamp Red TIMER lamp Green SWING lamp Orange SWING lamp Orange Operation can be checked by lighting and flashing of the display section OPERATION and TIMER lamps Perform judgement in accordan...

Страница 6: ...the remote control unit normal 2 Does each lamp light normally 3 Do not air flow direction louvers operate normally 4 Is the drain normal 5 Is there any abnormal noise and vibration during operation D...

Страница 7: ...nges must be made to the settings if the unit is to be used as a wired type 3 Changing the settings for the electrical circuits Switch 4 SW4 on the printed circuit board inside the electric compo nent...

Страница 8: ...be operated at the same time using a single remote controller 1 Wiring method indoor unit to remote controller 3 AUTO RESTART When the air conditioner power was temporarily turned off by a power fail...

Отзывы: