INSTALLATION
2 Installation
Do not install the unit near:
• places directly exposed to the sun's rays
• sources of heat
• humid environments and areas in possible contact with water
• environments with oil mist
• environments subject to high frequencies
Ensure that:
• the wall on which the unit will be installed has a suitable structure and capacity
• the area of the interested wall is not affected by tubes or electrical lines
• the interested wall is perfectly flat
• there is an area free of obstacles that may otherwise eventually compromise the
circulation of the incoming and outgoing air
• the installation wall is preferably an external perimeter wall to allow external
condensate drainage
• the flow of air is not aimed directly towards persons
The following descriptions of the various phases of assembly and relative drawings refer to a
machine version with couplings on the right-hand side.
To ensure successful installation and optimal performance, carefully follow the instructions
in this manual. Failure to apply the specified standards, which may subsequently cause the
malfunctioning of the equipment, shall release Frico from any warranty obligations and from
any responsibility for eventual damage caused to persons, animals or things.
The figure indicates the minimum distances from the wall and room furniture for the
assembly of the fan coil unit
2.1 Positioning the unit
2.2 Installation method
2.3 Minimum installation distances
GB