TROUBLE SHOOTING
Page 39
Page 39
Service Manual Bake Star intelligent
PKII
form 9123665 rev. 06/2013
Description of
part / function
Symptoms
Possible cause
Action
Door switch.
Blowers do not start up and
heaters stay off and/or
the message “door open”
appears while door is closed
Door switch (on doorlock)
defect or wiring loose.
Check door switch and/or
wiring.
See I/O test in service menu.
Blowers and heaters stay on
while door is opened.
Door switch broken or
came loose from door-
lock.
Check door switch and/or
wiring.
See I/O test in service menu.
Door
Door is leaking
Door gasket is damaged
or deteriorated.
Replace doorgasket.
Door adjustment not ok
Door does not close
smoothly
Door adjustment not ok
Door does not close or open Door adjustment not ok
Defect doorlock
Replace lock and / or catch