27
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the Calorie button for several seconds until the
test mode appears in the display.
Press the Calorie button again. Then, press the Power
Ramp increase or decrease button to calibrate the
ramp. The ramp will move upward and downward as it
calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calorie button repeatedly to exit the
calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, first unplug
the power cord.
Using a flat screw-
driver, release the
tabs on the Access
Cover (20) and pry
the Access Cover
upward off the
elliptical.
Next, look into the access opening and locate the Reed
Switch (69). Rotate the Large Pulley (74) until a Pulley
Magnet (75) is aligned with the Reed Switch.
Next, loosen, but do not remove, the indicated M4 x
16mm Screw (106). Slide the Reed Switch (69) slightly
toward or away from the Pulley Magnet (75). Then,
retighten the Screw.
Plug in the power cord and rotate the large pulley for
a moment. Repeat these actions until the console
displays correct feedback. When the reed switch is cor-
rectly adjusted, reattach the access cover.
MAINTENANCE AND TROUBLESHOOTING
20
69
106
75
74