FR500D Series Special Purpose Inverter for Elevator
- 46 -
5.3 ECN1313 PG Card
Outline and its interface
:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
COM
Y2
Y1
24V_COM
-
5V_GND
GND
A+
A-
B+
B-
CLK+
CLK-
DATA+
DATA-
Fig.C-8 EXC-PG05 ECN1313 PG terminals
Terminals
:
Model
Connecting Object
Pin Name
Description
EXC-PG05
ECN1313 Encoder
GND
24_COM,COM
24V output and its common
terminal
5V_GND,GND
5V output and its ground
A+,A-
A differential signal
B+,B-
B differential signal
Y1
B signal OC output (24V)
Y2
A signal OC output (24V)
CLK+, CLK-
ECN1313 differential clock input
DATA+, DATA-
ECN1313 differential data input
Usage method
1) Follow Figure C-1 to loading PG card
2) Shielded cable earthing line PE is connected directly to the fixed screw of PG card
3) According to the actual situation to set the inverter parameters as follow:
Parameter setting
Description
F00.08 = 3
Close-loop control(with PG card)
F08.24 = 3
Select the ECN1313 encoder