FR500D Series Special Purpose Inverter for Elevator
- 17 -
F00.25
Setting operation time
0
~
65535h(0: Invaild)
0h
×
Group F01: Frequency Given
F01.08
Maximum Frequency
(
Fmax)
20.00
~
600.00Hz
50.00Hz
×
F01.09
Upper Limit
Frequency(Fup)
Fdown
~
Fmax
50.00Hz
×
F01.10
Lower Limit
Frequency(Fdown)
0.00
~
Fup
0.00Hz
×
F01.11
Given frequency lower
than the frequency
control of lower limit
0
:
Run by the lower frequency
0
×
1
:
After running time of lower limit
frequency, it will run on speed of 0.
F01.12
Running time of lower
limit frequency
0.0
~
6000.0s
60.0s
×
Group F02: Control of Run/Stop
F02.00
Command Source
Selection of Run/Start
0
:
Operation Panel (LED off)
1
×
1
:
External Terminal (LED on)
2
:
Computer Communications
(LED flash)
F02.01
Running direction
0: Forward
0
×
1: Reverse
F02.03
Dead time between
forward and reverse
0.0
~
6000.0s
0.0s
×
F02.14
Stop DC braking current
0.0
~
150.0%
100.0%
×
F02.17
Dynamic brake
0: Disabled
1
×
1: Enabled
2: Enabled at running
3: Enabled at deceleration
F02.18
Dynamic Brake
Voltage
480
~
800V
700V
×
F02.19
Brake use ratio
5.0
~
100.0%
100.0%
×
F02.20
Output selection at 0Hz
0: No voltage output
1
×
1: voltage output
Group F03: Accel/Decel Parameters
F03.00
Acceleration Time1
0.00
~
600.00s
4.00s
△
F03.01
Deceleration Time1
0.00
~
600.00s
2.00s
△
F03.02
Acceleration Time2
0.00
~
600.00s
4.00s
△
F03.03
Deceleration Time2
0.00
~
600.00s
2.00s
△
F03.04
Acceleration Time3
0.00
~
600.00s
4.00s
△
F03.05
Deceleration Time3
0.00
~
600.00s
2.00s
△
F03.06
Acceleration Time4
0.00
~
600.00s
4.00s
△
F03.07
Deceleration Time4
0.00
~
600.00s
1.00s
△
F03.10
Accel/Decele curve
0: Linear Accel/Decel
1
×
1: S-curve Accel/Decel
F03.11
Initial segment time of
acceleration of S curve
0.00
~
600.00s
1.00s
×
F03.12
Time unit selection
0: 0.1s
1
×
1: 0.01s