FR500D Series Special Purpose Inverter for Elevator
- 21 -
F08.23
Encoder line number
0
~
10000
1024
×
F08.24
Encoder type
0:ABZ Incremental encoder
1:UVW Incremental encoder
2:Rotary encoder
3:ECN1313
4:ERN1387
0
×
F08.25
ABZ incremental
encoder AB phase
sequence
0
:
Positive
0
×
1
:
Negative
F08.26
Speed feedback PG card
disconnection detection
time
0.0: No action
0.1
~
10.0s
0.0s
×
F08.27
Motor and encoder
speed ratio
0.001
~
60.000
1.000
×
F08.30
Autotuning of motor 1
0: No autotuning
0
×
1: Static autotuning of motor
2: Rotary autotuning of motor
Group F09 V/f Control Parameters of Motor 1
F09.00
V/f curve setting
0: Linear V/f
1
×
1: Multi-stage V/f
2: 1.2nd power V/F
3: 1.4th power V/F
4: 1.6th power V/F
5: 1.8th power V/F
6: 2.0nd power V/F
7: V/F complete separation
8: V/F half separation
F09.01
Torque boost
0.0% (fixed torque boost)
0.1
~
30.0%
0.0%
△
F09.02
Cut-off frequency of
torque boost
0.00
~
Fmax
50.00Hz
△
F09.03
Multi-point V/F frequency
1(F1)
0.00
~
F09.05
0.00Hz
△
F09.04
Multi-point V/F voltage 1
(V1)
0.0
~
100.0
0.0%
△
F09.05
Multi-point V/F frequency
2(F2)
F09.03
~
F09.05
5.00Hz
△
F09.06
Multi-point V/F voltage 2
(V2)
0.0
~
100.0
14.0%
△
F09.07
Multi-point V/F frequency
3(F3)
F09.05
~
F09.09
25.00Hz
△
F09.08
Multi-point V/F voltage 3
(V3)
0.0
~
100.0
50.0%
△
F09.09
Multi-point V/F frequency
4(F4)
F09.07
~
Motor rated frequency
50.00Hz
△
F09.10
Multi-point V/F voltage 4
(V4)
0.0
~
100.0 Ue=100.0%
100.0%
△
F09.11
V/F slip compensation
gain
0.0
~
300.0%
80.0%
△