FR500D Series Special Purpose Inverter for Elevator
- 22 -
F09.12
Stator voltagedrop
compensation gain
0.0
~
200.0%
100.0%
△
F09.13
Excitation boost gain
0.0
~
200.0%
100.0%
△
F09.14
Oscillation Suppression
0.0
~
300.0%
100.0%
△
Group F10: Motor 1 Vector Control
F10.01
ASR low-speed
proportional gain Kp1
0.0
~
100.0
15.0
△
F10.02
ASR low-speed
integration time Ti1
0.001
~
30.000s
0.050s
△
F10.03
ASR switching frequency
1
0.00 Hz
~
F10.06
5.00Hz
△
F10.04
ASR high-speed
proportional gain Kp2
0.0
~
100.0
10.0
△
F10.05
ASR high-speed
integration time Ti2
0.001
~
30.000s
0.100s
△
F10.06
ASR switching frequency
2
F10.03
~
Fup
10.00Hz
△
F10.07
ASR input filtering time
0.0
~
500.0ms
3.0ms
△
F10.08
ASR output filtering time
0.0
~
500.0ms
0.0ms
△
F10.09
Vector control slip gain
50.0
~
200.0%
100.0%
△
F10.10
Digital setting of torque
upper limit in speed
control mode
80.0
~
200.0%
165.0%
×
F10.11
Excitation adjustment
proportional gain Kp1
0.00
~
10.00
0.50
△
F10.12
Excitation adjustment
integral gain Ti1
0.0
~
3000.0ms
10.0ms
△
F10.13
Torque adjustment
proportional gain Kp2
0.00
~
10.00
0.50
△
F10.14
Torque adjustment
integral gain Ti2
0.0
~
3000.0ms
10.0ms
△
Group F11 Protection Parameters
F11.00
Current limit control
0: Current limit disabled
2
×
1: Current limit mode 1
2: Current limit mode 2
F11.01
Current limit
100.0
~
200.0%
150.0%
×
F11.02
Frequency decreasing
time(limit current in
constant speed
operation)
0.0
~
6000.0s
5.0s
△
F11.03
Current limit mode 2
proportion gain
0.1
~
100.0%
3.0%
△
F11.04
Current limit mode 2
integral time
0.00
~
10.00s
1.00s
△
F11.10
Protection action 1
Unit's place: Bus under voltage
0: Fault reported and coast to
stop
1: Fault reported to the stop
mode
03000
×