FR500D Series Special Purpose Inverter for Elevator
- 30 -
search enable
1: Valid
H00.27
Light load direction
detection time
0.0
~
5.0s
1.0s
×
H00.28
UPS lower limit
0.0
~
200.0%
70.0%
×
H00.29
UPS lower limit error
0: Invalid
1: Valid
1
×
H00.30
Emergency mode
frequency given by
terminal
0: Invalid
1: Valid
0
×
H00.31
Emergency mode
intelligent drive output
0: Invalid
1: Valid
1
×
H00.32
Emergency mode
output percentage
0.0
~
100.0%
100.0%
×
H00.33
Emergency signal
running invalid time
0.0
~
1000.0s
60.0s
×
H00.34
Err41 overload times
setting
0
~
5
2
×
H00.35
Err41 times interval time
0
~
1000Min
60Min
×
H00.36
Err41 overload reset
time
0
~
1000s
120s
×
H00.37
Err41 overload reset
time timing
0s
⊙
H00.38
Err41 overload times
0
⊙
H00.39
S curve Time 5
0.00
~
60.00s
1.00s
△
H00.40
S curve Time 6
0.00
~
60.00s
1.00s
△
H00.41
Coefficient of S curve
time when short floor
function is enabled
0.00
~
1.00
0.7
△
H00.42
Percentage of torque
when leveling
0.0
~
120.0%
0.0%
×
H00.43
Torque boost Kp when
leveling
0.000
~
1.000
0.100
△
H00.44
Torque boost Ki when
leveling
0.000
~
1.000
0.300
△
H00.45
Duration for torque
boost
0.0
~
10.0s
1.0s
△
3.2 H00 group function code detailed explanation
H00.00
Special Purpose Inverter
Function Enable
0
:
Invalid
1
×
1
:
Valid
0
:
Invalid
1
:
Valid
Special purpose for elevator, group H00is valid
H00.01
Brake 0pen Delay
0.00
~
10.00s
0.00s
×
H00.02
Start Frequency
0.00
~
10.00Hz
5.00Hz
×
H00.03
Start Frequency Holding
Time
0.00
~
10.00s
0.00s
×
H00.04
Brake Release Delay
0.00
~
10.00s
0.30s
×
H00.05
Brake Open Frequency
(Rising)
0.00
~
10.00Hz
1.00Hz
×
H00.06
Brake Release
Frequency (Rising)
0.00
~
10.00Hz
0.20Hz
×
H00.07
Brake Open Frequency
0.00
~
10.00Hz
1.00Hz
×