INSTALLATION INSTRUCTION MANUAL
TANK DRAWDOWN
4. Add a second 25 to 80 psi sensor to the system. The pressure setting on the
additional sensor will need to be set below the regulating sensor, but above the tank
pre-charge pressure. The pressure can be adjusted once the system is up and running.
5. Use the supplied 6 conductor pressure sensor cable to attach the sensor cable to
the sensor as shown. (See Figure 1, pg 5, for Wiring)
6. Bring the sensor cable into the drive via the knockout at the bottom. (Be sure
to follow local codes requiring conduit or sealing practices. In order to maintain a
NEMA 4 rating, a connector must be used.)
3
Содержание SubDrive NEMA 4
Страница 1: ...SubDrive Tank Drawdown Installation Instruction Manual 225770901...
Страница 3: ...INSTALLATION INSTRUCTION MANUAL TANK DRAWDOWN...
Страница 4: ...INSTALLATION INSTRUCTION MANUAL TANK DRAWDOWN...
Страница 15: ...INSTALLATION INSTRUCTION MANUAL TANK DRAWDOWN Notes...
Страница 16: ...INSTALLATION INSTRUCTION MANUAL TANK DRAWDOWN Notes...