8. Connect the black wire from the cut-in pressure switch to the Normally Closed
(NC) terminal on the Auxiliary Relay Board. Connect the Red wire from the
regulating pressure switch to the Normally Open (NO) terminal on the Auxiliary
Relay Board.
9. Connect the orange and blue wires to the shut-off terminals.