background image

APPLICATION

These pumps are suitable for transferring liquid fertilizer, where the 
vertical distance from the pump to the liquid level does not exceed 25 
ft. (7.6m). The elevation above sea level and friction losses must be 
taken into consideration. This pump has been tested and operated 

  SAFETY: CAREFULLY READ THESE SAFETY 

MESSAGES IN THIS MANUAL AND ON PUMP.

 CAUTION

• 

DO NOT OPERATE THIS PUMP DRY!

• 

Review instructions before operating.

 WARNING

.

 

Ensure input drives are properly aligned and guarded before 
operating.

Keep all shields and guards in place.

under actual working conditions. Motor, pump and all accessories 
found satisfactory. If pumping unit is not performing as specifi ed, 
check installation and follow instructions carefully.

PERFORMANCE

Model

HP

Total Head in Feet

20

30

40

50

60

70

80

Flow in GPM

FBSTF-1

1

69

63

45

17

FBSTF-2

2

127

118

103

77

52

23

FBSTF-3

3

150

142

125

100

69

35

FBSTF-5

5

267

240

207

164

110

45

(Based on 3450 RPM)

INSTALLATION

a)

 

LOCATION (Refer to Fig. 1):

 If the pump is intended to be perma-

nently installed, the location should be clean, dry and ventilated. It 
should also provide adequate room for drainage and servicing.

 

The pump should always be located as close as possible to the 
source of liquid it will be pumping. This will keep the friction losses 
at a minimum and pumping capacities as high as possible.

b)

 

MOUNTING:

 It is recommended that a rigid frame be constructed 

to mount the pump transmission and the power source to it in 
order to maintain proper shaft alignment. To eliminate creeping, 
due to vibration secure the frame to a rigid foundation.

c) ALIGNMENT:

 Proper alignment is essential for good mechanical 

pump operation and satisfactory life of the transmission 
components.

 

To check proper alignment using a coupling, lay a straight edge 
across both coupling halves. Both halves should line up with the 
straight edge. Rotate the coupling to check at 3 or 4 positions 

and adjust pump unit and/or power source accordingly.

 

To check for proper alignment using a belt, make sure that the 
pulley(s) are in line with each other.

d)

 

SUCTION LINE:

 It is recommended that the size of the suction 

line be the same as the tapping size on the pump casing. If the 
pump is installed any appreciable distance away from the source 
of liquid supply, the suction line should be increased by one size. 
The suction line must always slope upwards to the pump to avoid 
air pockets in the line.

e)

 

SUCTION PIPE: 

Use thread compound on all pipe joints. 

Connections must be tight. Clean, uncorroded pipe is 
recommended.

f)

 

SUCTION HOSE:

 If the suction line runs basically vertical, use 

an elbow on the hose to prevent kinking. Use thread compound 
on all hose joints. Connections must be tight.

FBSTF SERIES
Self-Priming Centrifugal Pumps

OWNER'S MANUAL

 WARNING

.

 

Review chemical manufacturer's safety precautions before 
handling.

Make sure all connections are tight.

Do not breathe or ingest fumes or chemicals.

Never use with fl ammable fl uids.

BEFORE OPERATING OR INSTALLING 
THIS PUMP, READ THIS MANUAL AND 
FOLLOW ALL SAFETY RULES AND 
OPERATING INSTRUCTIONS. 

SAFETY WARNINGS

Содержание FBSTF Series

Страница 1: ...nd the power source to it in order to maintain proper shaft alignment To eliminate creeping due to vibration secure the frame to a rigid foundation c ALIGNMENT Proper alignment is essential for good m...

Страница 2: ...also free of liquid b STORAGE It is recommended to use a good rust inhibitor in the casing after draining procedure has been completed REPAIR 3 4 2 HP MODELS DISASSEMBLY 1 Drain the pump see DRAINING...

Страница 3: ...will be leaking through the middle of the adapter Replace seal Air pockets or leaks in the suction line Check suction line Clogged impeller Remove casing to clean out Pump loses prime Liquid level dr...

Страница 4: ...er or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums...

Страница 5: ...ONTAGE Nous vous recommandons de construire un cadre rigide pour y monter la transmission de la pompe et la source d alimentationafindeconserverl alignementappropri del arbre Pour liminer le d placeme...

Страница 6: ...l n y a plus d eau dans la roue de turbine S assurer galement que les conduites sont vidang es b ENTREPOSAGE Il est recommand d utiliser un inhibiteur de rouille de bonne qualit dans le bo tier apr s...

Страница 7: ...conduite d aspiration V rifier la conduite d aspiration La roue de turbine est obstru e Enlever la bo tier pour le nettoyer La pompe se d samorce Le niveau de liquide est inf rieur l extr mit de la c...

Страница 8: ...tion de proc dures d installation d op ration d entretien ou d entreposage non conformes ou pour cause d utilisation exc dant les maximums recommand s tel que stipul dans les instructions concernant l...

Страница 9: ...del tubo Las conexiones deben estar apretadas Se recomienda que el tubo est limpio y sin corrosi n MANGUERADESUCCI N Silal neadesucci nest dispuesta en general verticalmente utilice un codo en la man...

Страница 10: ...edado alg n l quido Aseg rese de que las l neas tambi n est n libres de l quidos b ALMACENAMIENTO Serecomiendautilizarunbuenantioxidante en la caja despu s de haber completado el procedimiento de dren...

Страница 11: ...a ada 3 Se perder l quido por el medio del adaptador Reemplace la junta Burbujas o p rdidas en la l nea de succi n Verifique la l nea de succi n Turbina obstruida Retire la caja para limpiarla La bomb...

Страница 12: ...ado por negligencia abuso accidente aplicaci n indebida modificaci n alteraci n instalaci n inadecuada operaci n mantenimiento o almacenamiento o como resultado del abuso de los l mites recomendados...

Отзывы: