8 DISPOSAL 

Disposal of this product or parts of it must be carried out using the local public or 
private waste disposal systems.

9 TROUBLESHOOTING 

 

WARNING:  Before any repairs to the electric pump, check that the power 
supply  is  disconnected  and  that  it  cannot  be  accidentally  reconnected 
during maintenance operations.

 

WARNING:  If the electric pump is used for hot and/or hazardous liquids, it is 
essential to inform the personnel who will carry out the repair. In this case, 
clean the pump so as to ensure the safety of the operator.

 

For 

problems 

and 

solutions, 

consult 

table 

below: 

“TROUBLESHOOTING TABLE”

N

O

I

T

C

A

E

S

U

A

C

 

M

E

L

B

O

R

P

9.1

The pump turns but does 

not deliver

a)

The internal parts are obstructed by foreign bodies: 

Dismantle the pump and clean it.

b)

Inlet pipe is blocked: 

Clean the pipe.

c)

Air is entering the inlet pipe: 

Check that the pipe is airtight right up to the pump and seal it.

d)

The pump is unprimed: 

Re-prime it by filling the pump. Check that the base valve is 

airtight.

e)

Inlet pressure is too low and generally accompanied by 

cavitation noise:

Excessive loss of head in suction or the suction height is 

excessive (check the NPSH of the installed pump).

f)

Voltage insufficient to power the motor: 

Check the voltage of the motor terminals and the correct 

diameter of the conductors.

9.2

The pump vibrates 

a)

Anchorage on a faulty base: 

Check and fully tighten the nuts on the bolts of the studs.

b)

Foreign bodies obstructing the pump: 

Dismantle the pump and clean it.

c)

Obstruction to the pump rotation: 

Check that the pump can rotate freely without any abnormal 

resistance.

d)

Faulty electrical connection: 

Check the pump connections.

9.3

The motor heats up 

abnormally

a)

Insufficient voltage: 

Check the voltage of the motor terminals. The voltage should 

be ± 10% of the rated voltage.

b)

Pump blocked by foreign bodies: 

Dismantle the pump and clean it.

c)

Ambient temperature more than +40°C: 

The motor is designed to function at a maximum ambient 

temperature of +40°C.

d)

Connection error in the terminal board: 

Check that the connections respect the diagram shown inside 

the cover of the terminal box and the data plate information.

9.4

The pump does not deliver 

sufficient pressure

a)

The motor is not rotating at normal speed (foreign bodies 

or faulty power supply etc.)

Dismantle the pump and correct the problem.

b)

The motor is faulty: 

Replace it.

c)

The pump is not filling properly: 

Repeat the priming operation.

d)

The motor rotates in reverse (three-phase motor): 

Invert the direction of rotation by exchanging two phase wires 

on the motor terminal board or the electrical control panel.

e)

Voltage insufficient to power the motor: 

Check the voltage of the motor terminals and the correct 

diameter of the conductors.

9.5

The automatic circuit 

breaker trips

a)

Thermal overload relay value too low: 

Control the intensity with an ammeter, set the value of the 

intensity shown on the motor rating plate.

b)

Voltage is too low: 

Check that the diameter of the conductors of the electric cable 

is correct.

c)

Interruption of one phase: 

Check the electric cable or fuse and replace if necessary.

d)

The thermal overload relay relay is faulty: 

Replace it.

9.6

The flow is not regular 

a)

The inlet height is not being observed: 

Check the installation conditions and the recommendations of 

this manual.

b)

The inlet piping has a smaller diameter than the pump:

The inlet piping should have the same diameter as the inlet 

mouth.

c)

The suction filter and inlet piping are partially blocked:

Clean the inlet duct.

TROUBLESHOOTING TABLE:

Содержание EH 15/2

Страница 1: ...es multietapas Serie MH Series MH HORIZONTAL MULTI STAGE PUMP MH Operating and maintenance manual 2 BOMBAS HORIZONTALES MULTIETAPAS MH Manual de instrucciones de empleo y manutención 4 Operating and maintenance manual Manual de uso y mantenimiento ...

Страница 2: ... Directive 2009 125 E RULING EC 640 2009 MOTOR 3 50Hz PN 0 75 kW 50Hz if marked IE2 or IE3 and with the following technical standards EN 809 2009 EN 60335 1 2013 EN 60335 2 41 2005 EN 62233 2005 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60034 30 1 2014 The person authorised to compile the technical file is Franklin Electric s r l Via Asolo 7 36031 Dueville VI Dueville 01 03 2015 Riccardo Fornasa Dire...

Страница 3: ...maximum height between the pump and the level of the liquid is 4 1 metres 5 2 Verifying maximum pressure Working pressure It is important to keep the sum of the inlet pressure plus the maximum pressure of the pump at zero capacity always lower than the maximum allowed working pressure PN The PN maximum working pressure is shown on the data plate see point 4 3 5 3 Minimum rated capacity WARNING The...

Страница 4: ...without proper protection Do not place inflammable material near to the pump WARNING The electric pump must NOT be started without first being filled Its use without liquid may permanently damage the mechanical seal Do not operate the pump with the inlet and discharge valves closed for more than 5 seconds Do not expose the pump when idle to freezing temperatures Frozen liquid will damage the pump ...

Страница 5: ...nection Check the pump connections 9 3 The motor heats up abnormally a Insufficient voltage Check the voltage of the motor terminals The voltage should be 10 of the rated voltage b Pump blocked by foreign bodies Dismantle the pump and clean it c Ambient temperature more than 40 C The motor is designed to function at a maximum ambient temperature of 40 C d Connection error in the terminal board Che...

Страница 6: ...lectromagnética 2004 108 CE Diseño ecológico 2009 125 CE REGLAMENTO CE 640 2009 MOTOR 3 50Hz PN 0 75 kW 50Hz si lleva la marca IE2 o IE3 y a las siguientes normas técnicas EN 809 2009 EN 60335 1 2013 EN 60335 2 41 2005 EN 62233 2005 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60034 30 1 2014 La persona autorizada a redactar el expediente técnico es Franklin Electric s r l Via Asolo 7 36031 Dueville VI ...

Страница 7: ...guiente H pb x 10 2 NPSH Hf Hv Hs pb Presión barométrica o presión del líquido en aspiración bar NPSH Carga neta positiva en aspiración m fig 7 Hf Pérdida de carga en el tubo de aspiración al máximo caudal de la bomba m Hv Presión de vapor m en función de la temperatura del líquido tm ver fig 2 A Hs Margen de seguridad m mínimo 0 5 Si el valor obtenido es menor que 0 la bomba se debe instalar por ...

Страница 8: ...n absoluto el contacto de los cables eléctricos con los tubos y demás partes de la bomba Aislar bien los cables de la humedad Apretar bien los prensaestopas para impedir que la humedad entre en la bornera y para garantizar protección contra el desplazamiento de los cables Los motores eléctricos pueden funcionar a la tensión de alimentación indicada en la placa con tolerancia 10 Los motores eléctri...

Страница 9: ...está cebada Cebarla llenándola Verificar la estanqueidad de la válvula de fondo e La presión en aspiración es demasiado baja y generalmente está acompañada de ruidos de cavitación Demasiada pérdida de carga en aspiración o altura de aspiración excesiva controlar el NPSH de la bomba instalada f Motor alimentado con tensión insuficiente Controlar la tensión de los bornes del motor y la sección de lo...

Страница 10: ...Installation and disassembly diagram Esquema de instalación y desmontaje Serie MH 00114145 10 2015 Fig 1 A B C ...

Страница 11: ... 15 12 10 8 0 6 0 5 0 4 0 3 0 2 0 1 0 0 8 0 6 0 4 0 3 0 2 0 1 1 5 120 110 90 100 80 70 60 50 40 30 20 10 0 150 130 140 25 35 45 40 30 160 170 180 190 62 79 100 126 Hv m tm C Pb H A B Fig 3 Fig 4 70 60 50 40 30 20 10 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Temp C Altitude m 80 85 90 95 100 Fig 2 ...

Страница 12: ...Installation and disassembly diagram Esquema de instalación y desmontaje Serie MH 00114147 11 2015 A A2 A3 100 mm 2 6 7 3 4 2 1 1 2 8 1 5 B A1 Fig 5 Tmax 90 C Tmax 110 C U T F V ...

Страница 13: ... 6 A EH 5 3 103 Rp 1 Rp 1 258 361 70 100 6 EH 5 4 127 Rp 1 Rp 1 258 385 70 100 6 EH 5 5 151 Rp 1 Rp 1 258 409 70 100 6 EH 5 6 175 Rp 1 Rp 1 300 475 70 128 1 EH 5 7 199 Rp 1 Rp 1 300 499 70 128 1 180 EH 5 8 223 Rp 1 Rp 1 300 523 70 128 1 204 EH 5 9 247 Rp 1 Rp 1 300 547 70 128 1 228 Pump Model A DN1 DN2 E F L1 L2 L3 EH 9 2 118 Rp 1 Rp 1 262 380 74 100 6 A EH 9 3 118 Rp 1 Rp 1 262 380 74 100 6 EH 9 ...

Страница 14: ... 2015 NPSH m h l min U S gpm feet m 00114161 opm 11 2015 NPSH m h l min U S gpm feet m 0 16 12 8 4 00114162 opm 11 2015 NPSH m h l min U S gpm feet m 0 0 0 0 0 4 8 12 16 20 24 28 2 4 6 8 4 8 12 16 20 24 100 200 300 400 20 40 60 80 100 120 00114163 opm 11 2015 NPSH m h l min U S gpm feet m 0 20 40 60 80 100 120 140 0 100 200 300 400 500 0 4 8 12 16 20 24 00 4 8 12 16 20 24 32 28 2 4 6 8 EH5 50 Hz ...

Страница 15: ...als 30 07 Ball bearings and lip seal 30 08 Rotor and pump shaft 30 09 Screws nuts and washers 30 10 Motor foot 30 11 Valve plug 40 00 Stage housing and diffuser 40 01 Last stage with holes 40 02 Floating neck ring assembly 40 03 Initial stage housing 50 00 Impeller 5001 Impeller spacers Fig Fig 8 EH Series pump section and List of Main components EH 3 5 9 00114149 11 2015 30 05 30 05 20 05 20 03 2...

Страница 16: ...ast stage with holes 40 02 Floating neck ring assembly 40 03 Initial stage housing 40 04 Stage housing and diffuser with bearing 50 00 Impeller 50 01 Impeller spacers 50 02 Intermediary sleeve 50 03 Intermediary sleeve spacer Fig 9 EH Series pump section and List of Main components EH 15 20 00114149 11 2015 00114149 11 2015 30 05 30 05 20 05 30 09 20 05 30 05 30 05 20 02 20 01 30 11 30 07 10 00 30...

Отзывы: