MAINTENANCE

Poppet Check Valve

5

MAINTENANCE

Poppet Check Valve

Use a T-Handle Poppet Wrench (part no. 106964101), 
ordered separately, or standard needle nose pliers to 
remove the poppet assembly by turning clockwise.
If reinstalling, tighten to 15 inch-pounds.

Troubleshooting

Risk of damage to pump or other equipment.

Fluid draining back through the pump can cause the pump to rotate backwards. If pump/motor starts during this time, damage to 

the pump can occur.

Poppet Assembly

T-Handle Poppet Wrench

Problem

Probable Causes

Corrective Action

Pump fails to start

Electrical trouble

Call dealer or electrician

Draw-down protection device 

has pump turned off

Make sure system check valves are correctly installed or uninstall draw-down 

protection device. Reset low pressure cutoff switch (if installed).

Overload tripped

Reset overloads and low pressure cutoff switch (if installed).

Pump fails to deliver 

water or reduced out

-

put

Clogged intake screen

Clean intake screen.

Insufficient well yield

Shut off system. Refer to 

“Low-Yielding Well” on page 4

.

Worn pump

Replace pump.

Low voltage

Make sure the power supply corresponds with the electrical rating of the 

motor. For 3-wire, single phase pumps, check the control box.

Incorrect rotation (3-phase)

Interchange any two leads at the magnetic starter.

Pump cycles too fre

-

quently

Pressure drop between pres

-

sure switch and tank.

Check system for a plumbing leak and correct as necessary.

“Cut-in” or “Cut out” pressure 

too high.

Follow manufacture’s instructions to properly set the on/off cycle of the pres

-

sure switch.

Waterlogged pressure tank

Follow manufacturer’s instructions on resetting/establishing proper air pres

-

sure setting for the tank.

Electrodes of floatless liquid 

level control too close together.

Follow manufacture’s recommendation for installation of the electrodes on 

the level control.

Tank too small.

Install pressure tank with bonded diaphragm, air cell, or water bag.

Overloads trip

Electrical trouble

Call dealer or electrician.

Pressure switch cycles 

rapidly

Pressure switch too far from 

pressure tank

Adjust air charge of tank to manufacturer’s recommendations.

Backspin

Failed or no check valve

Install new, non-swing type check valve(s).

Upthust

Check valve drilled

Install positive sealing check valves only.

Water Hammer

Lowest check valve leaks or is 

more than 30 ft above water

Shut system down and contact pump installer to correct issue.

Check valve drilled

Install positive sealing check valves only.

Содержание E Series

Страница 1: ...r operation procedures and all applicable codes may result in the following hazards Risk of severe injury or death by electrical shock Ground motor before connecting to power supply To reduce risk of electrical shock disconnect power before working on or around the system More than one disconnect switch may be required to de energize the equipment before servicing Wire pump system for correct volt...

Страница 2: ...ere is an adequate flow of water over the motor for cooling purposes is ensured Determine the correct pump setting from the driller s record taking into account the static water level and the draw down at the proposed pumping rate Pressure Tank Pressure Switch Gate Valve Service Pipe Pressure Gauge Pressure Relief Valve Spring Loaded Check Valve See Wiring Diagrams Sanitary Well Seal or Pitless Ad...

Страница 3: ...nd apply power momentarily 8 Ensure pump rotation is clock wise when viewed from pump discharge 9 Place the motor and pump labels in the circuit breaker box for future reference Physical Installation Refer to Typical Installation on page 2 1 Confirm that the motor s lead wires are secure under the pump s lead guard 2 Install a pressure tank per manufacturer s recommendations 3 Attach a 3 16 diamet...

Страница 4: ... well and above well screen or casing perforations 9 Test the well Refer to Well Test on page 4 10 Place a sanitary well seal or pit less adapter over top of well per manufacturer s recommendations Well Test 1 Install a partially opened gate valve on the end of the pipe 2 Start the pump and slowly open valve to full flow 3 If the discharge water is not clear within 30 minutes stop pump and take ne...

Страница 5: ...trical rating of the motor For 3 wire single phase pumps check the control box Incorrect rotation 3 phase Interchange any two leads at the magnetic starter Pump cycles too fre quently Pressure drop between pres sure switch and tank Check system for a plumbing leak and correct as necessary Cut in or Cut out pressure too high Follow manufacture s instructions to properly set the on off cycle of the ...

Страница 6: ...ting ft m Drop Pipe Size Wire Size pump to control box Wire Size control box to power source Horizontal Offset between well house Materials of Construction 3 Phase Panel Info Standard Soft Start or VFD Power Supply Options Utility Generator or Alternative Energy Source Make of Pump Amps HP Volts Ph Make of Control Box HP Volts Power Supply Volts HZ Pressure Switch PSI Cut in Cut out ...

Страница 7: ...NOTES ...

Страница 8: ...800 348 2420 franklinwater com For technical assistance parts or repair please contact Form 106259101 Rev 003 06 20 Copyright 2020 Franklin Electric Co Inc All rights reserved ...

Отзывы: