9
10/17 |
036865-047
KEP8AC FAMILY
Outlet Tube (insulated plastic)
VALVE
STEP 1:
With the cooler top removed, find the tube going from the cooling
tank outlet to the valve. The TEE fitting (supplied) will need to con-
nect between the cooling tank and valve.
(Figure 3)
To retrofit the Bottle Filler to an existing unit, follow the
instructions below.
If the cooling tank is non-pressurized, then go to the addendum section, "Pressurizing the cooling tank". Other-
wise, proceed to Step 1 below. Non-pressurized units are SINGLE units made since December of 2009. Refer
to the schematic below to identify the system you have.
PRESSURIZED
COOLING TANK
NON-PRESSURIZED
COOLING TANK
Co
oli
ng
tank
Water
valve/regulator
Supply
Water
Water
valve/regulator
Supply
Water
Co
oli
ng
tank
FIGURE 1
FIGURE 2
FIGURE 3
SECTION 3: INSTALLATION
B. CONNECTING THE WATER LINE (continued)