12. Troubles, causes and troubleshooting
Trouble
Possible cause
What to do about it
Machine is not running
or switches off during
operation
No current; low voltage
Have an expert:
Check the fuse of local
installation and control fuses in
the circuit box of the machine,
replace if necessary; check
supply cable, wall socket and
voltage
Excessive pump pressure,
motor protection switch cuts out
See also „Excessive pump
pressure“
Pump fails to reach
prescibed pressure
Leakage in the pump or in
chemical suction hose
Check and retighten screw
connections, replace sealings
if necessary, tighten hose clips;
check dosing valve for leaks,
replace, if necessary
Pump seal leaking
Have an expert check pump
seals and plungers for wear
conditions and replace, if
necessary
Spray nozzle worn out
Replace spray nozzle
Wrong spray nozzle
Screw in proper spray nozzle
Clean filter
Pump pressure too
high
Nozzle blocked
Remove and clean nozzle, flush
spray lance without nozzle
Wrong spray nozzle
Mount correct screw
Heating coil delimed
Delime heating coil
With the spray gun
closed, the machine
switches on and off
permanently
Leakage in the pressure system
Check pipes, hoses, fittings,
spray gun for leaks, fix seals,
on leaking parts or have them
replaced by an expert
No flow of cleansing
agents
Cleansing agent filter on
suction hose blocked
Clean filter
Dosing valve blocked
Clean dosing valve
Cleansing agent tank empty or
filter basket on suction hose is
not below liquid level
Refill cleansing agents, lower
filter basket