Maintenance and care
113
14.3.2 Checking the liquid level and filling the sealer
• Check the liquid level in the sealer regu-
larly.
Make sure the sealer is always filled at least
to the ‘Min’ mark to prevent the felts from dry-
ing up. When felts with glue residues dry up
they harden to the point of becoming prema-
turely useless.
Filling the sealer
• Separate the sealer from the franking
machine: Slightly lift the franking machine
on the left side and pull the sealer away to
the left.
• Swing up the rocker with the moistening
felt.
The filler hole for topping up the sealer is now
accessible.
• Fill the sealer with ‘sealit’. This special
sealing liquid is available from Francotyp-
Postalia.
Using tap water is possible. Note, however,
that the sealing process may be less reli-
able when using water.
• Check the liquid level. The liquid level in
the sealer should roughly reach to the
‘Max’ mark.
• Swing down the rocker.
• If necessary: dry the sealer.
• Connect the sealer to the franking
machine.
Francotyp-Postalia offers a special bottle
with filling hose as accessory. This bottle lets
you top up the sealer right at the installation
site.
Lateral liquid
level gauge
Rocker with
moistening felt
Filler hole
Содержание optimail 30
Страница 1: ...Franking machine Operator Manual optimail 30 ...
Страница 131: ...Appendix Menu overview 131 Menu overview ...
Страница 137: ...Appendix Declaration of Conformity 137 D e c l a r a t i o n o f C o n f o r m i t y ...
Страница 138: ...optimail 30 Operator Manual 138 ...
Страница 145: ...For your notes 145 ...
Страница 146: ...For your notes 146 ...
Страница 148: ...51 0034 3089 00 Rev 04 2011 03 xxx helbig berlin ...