background image

Page 2

Do not return sprayer to store, if you experience problems or have questions contact

our toll free Customer Service Center, M-F 8A.M. - 5P.M., EST, at 1-800-311-9903, or

e-mail: [email protected], or access online at: www.TheFountainheadGroup.com.

     SAFETY PRECAUTIONS

• Read owner’s manual completely before operating this sprayer.

• Always use goggles, gloves, and protective clothing when using sprayer.

• Read and follow all instructions and cautions on label of products used in this sprayer.

• Never use flammable liquids, caustics, acids, or hot water in this tank.

• Do not leave sprayer in the sun when not in use.

• Spray when air is calm to prevent drift of chemicals.

• Do not use sprayer near open flame or anything that could cause ignition of the spray.

• Always inspect hose and all hose connections before each use. A damaged hose, or loose hose

  connection can result in unintended exposure to the pressurized chemical, resulting in serious injury or 

  property damage.

• Do not lift or carry sprayer by the hose, shut-off valve, or extension. Carry by pump handle only, 

  making sure handle is properly locked in place before lifting.

• Do not pressurize with any mechanical device such as an air compressor, since this can create a

  dangerous pressure level and bursting of parts resulting in serious injury. Only use original pump.

• Do not store chemicals in this tank.

• Always release pressure when sprayer is not in use and before removing pump from tank.

• Do not stand with face or body over top of tank when pumping or loosening pump, to prevent pump or 

  solution from striking you, resulting in serious injury.

• Clean and rinse sprayer thoroughly after each use.

• Never attempt to alter sprayer from original condition.

• Always use replacement parts from original manufacturer.

• Keep the sprayer and all chemicals out of the reach of children.

     WARNING

The sprayer is operated with liquid under pressure. Failure to observe caution and to follow instructions 

for operating and cleaning can cause tank, hose and other parts to be weakened and rupture under

pressure. This can result in serious injury from high pressure discharge of liquids or forcible ejection of 

parts. Do not use flammable materials in this sprayer. Material could ignite or explode, causing serious 

injury and/or possible death. For safe use of this product, you must read and follow all instructions before 

use. 
                            

TEST SPRAYER WITH WATER BEFORE USING ANY CHEMICALS.

      CAUTION

Always empty, clean and dry tank, pump system, shut-off, hose, and extension after each use. FAILURE TO 

DO SO MAY WEAKEN SPRAYER COMPONENTS, CAUSING COMPONENTS TO RUPTURE WHEN PRESSURIZED. 

Additionally, FAILURE TO CLEAN AND PROPERLY MAINTAIN YOUR SPRAYER WILL VOID MANUFACTURER’S 

WARRANTY.

      

WARNING

ALWAYS CLEAN THE SPRAYER AND SHUT-OFF THOROUGHLY AFTER EACH USE 

OR WHEN CHANGING APPLICATIONS AS DESCRIBED IN THE CLEANING SECTION.  

FAILURE TO COMPLETELY CLEAN MAY CAUSE CROSS-CONTAMINATION.

Содержание D.B.Smith

Страница 1: ...r To The Store For Help Information or Parts Call 1 800 311 9903 The Fountainhead Group Inc 23 Garden St New York Mills NY 13417 1 800 311 9903 www TheFountainheadGroup com CAUTION Read and follow all instructions Use and Care Manual D B Smith Professional Series Sprayers O Style R Style ...

Страница 2: ... Always release pressure when sprayer is not in use and before removing pump from tank Do not stand with face or body over top of tank when pumping or loosening pump to prevent pump or solution from striking you resulting in serious injury Clean and rinse sprayer thoroughly after each use Never attempt to alter sprayer from original condition Always use replacement parts from original manufacturer...

Страница 3: ...ustable Cone Nozzle D Red High Volume Fan Nozzle E Yellow Low Volume Fan Nozzle F Flat Seal G Adapter H Extension C A G B D F H E ADJUSTABLE CONE USES Spot spraying in or around flower beds trees and shrubs Edging along fences driveways and walkways Killing brush such as poison ivy poison oak kudzu and wild blackberry Preparing garden beds for planting of ornamentals and vegetables For precision s...

Страница 4: ... to the desired level See fill markings on side of tank Always refer to chemical manufacturer for proper mixture 3 Install the pump into the tank opening and turn clockwise until tightly sealed against the tank See Figure F Figure F Figure E Pressurizing 1 Make sure shut off lock is not engaged If shut off lock is engaged while pressurizing the unit will immediately start spraying 2 Push down on t...

Страница 5: ...ressurizing section 8 Direct the nozzle away from you and activate the shut off for at least 30 seconds to clean the hose and shut off 9 Release pressure as described in the Release Tank Pressure section 10 Remove the pump and empty the contents into gravel or bare soil 11 Repeat steps 5 10 until thoroughly cleaned Finish 1 Depressurize the tank as described in Release Tank Pressure section 2 Turn...

Страница 6: ...e cap securely turn the barrel clockwise to lock the tabs in place Figure 5 R Style 1 Inspect gasket If worn or damaged remove and replace See Figure 6 2 To remove pump cap from pump barrel remove screws securing pump cap to barrel See Figure 7 3 Inspect o ring If worn or damaged remove and replace Lubricate o ring with petroleum jelly See Figure 8 4 Inspect check valve in bottom of barrel If worn...

Страница 7: ...tion 4 Replace if worn or damaged as described in Pump Disassembly Reassembly section Sprayer material overflows through pump barrel or pump handle rises when handle is unlocked 1 Dirt or debris under check valve 2G 5H or 6A on pump 2 Chipped torn or swollen pump check valve 2G 5H or 6A 1 Clean check valve 2G 5H or 6A and valve sealing surface on pump 2 Replace check valve 2G 5H or 6A as described...

Страница 8: ... 2A 2C 2E 2F 2G 1 1 1 2 1 3 2D KIT 2 5B 5A 5C 5D 5F 5G 5H 4 5E 3 2 3 3 KIT 5 9A 9F 10F 10B 10D KIT 9 KIT 10 7 21 7 18 11A KIT 11 11G 11F 11E 11D 11B 9B 9E 9C 9D 11C 10E 10C 10A 8 1 8 3 8 2 11E 11F 11C 11D 11A 11B R O 7 SS 6A 6B 6C KIT 6 6C ...

Страница 9: ...II SS 182112 21 EXTENSION ASSEMBLY STAINLESS STEEL SMITH PRO II 1 181817 SHUT OFF ASSEMBLY SMITH PRO II 1 GAL 2 181818 SHUT OFF ASSEMBLY SMITH PRO II 2 GAL 3 181819 SHUT OFF ASSEMBLY SMITH PRO II 3 GAL KIT 11 181910 SMITH PRO II SHUT OFF SERVICE KIT 11A 181493 VALVE BODY O RING 11B 181840 POPPET SEAL 11C 181231 BARB O RING 11D 181468 FILTER 11E 181812 FLAT NOZZLE SEAL 2 11F 181810 WAND O RING 11G ...

Страница 10: ...SSORIES ARE AVAILABLE BY CONTACTING The Fountainhead Group Inc Customer Service Center Monday Friday 8 A M 5 P M EST Toll Free 1 800 311 9903 or e mail Info TheFGI com or Access online at www TheFountainheadGroup com Page 10 ...

Страница 11: ... ayuda información o piezas llame al 1 800 311 9903 The Fountainhead Group Inc 23 Garden St New York Mills NY 13417 1 800 311 9903 www TheFountainheadGroup com PRECAUCIÓN Lea y siga todos las instrucciones Estilo O Estilo R Manual de uso y cuidado D B Atomizadores de la Serie Profesional Smith ...

Страница 12: ...s Sólo use la bomba original No almacene sustancias químicas en este tanque Siempre alivie la presión cuando el rociador no está en uso y antes de quitar la bomba del tanque No se pare con lacara o el cuerpo sobre la parte superior del tanque cuando bombea o afloja la bomba para evitar que la bomba o la solución le haga contacto con su querpo resultando en lesión grave Limpie y enjuague el atomiza...

Страница 13: ...ara espuma C Boquilla de cono adjustable D Boquilla roja con ventilador para alto volumen E Boquilla amarilla con ventilador para bajo volumen F Sello plano G Adaptador H Extensión C A G B D F H E Usos de las boquillas cono ajustables Rociado localizado en o alrededor de arriates árboles o arbustos Bordes a lo largo de cercas entradas y caminos Destrucción de malezas por ejemplo hiedra venenosa ro...

Страница 14: ...hacia abajo el mango y gírelo en sentido antihorario para destrabar el mango Vea la Figura G 1G 3 Presurice el atomizador bombeando el mango con un movimiento uniforme hacia arriba y hacia abajo Vea la Figura G 2G 4 Empuje el mango hacia abajo y gírelo en sentido horario para trabar el mango en la bomba Vea la Figura G 3G Figura G 1G 2G 3G Libere la presión del tanque Válvula de liberación de pres...

Страница 15: ...n sentido antihorario para quitar la bomba 3 Vacíe todo el líquido restante de acuerdo con las intrucciones de desecho del producto 4 Siga las instrucciones de Limpieza INSTRUCCIONES DE OPERACIÓN continuación Alamacenamiento del atomizador 1 El tanque del atomizador debe colgarse en posición invertida y sin la bomba 2 No almacene ni deje solución dentro del tanque después del uso 3 Guárdelo en un ...

Страница 16: ...llas en su lugar Estilo R 1 Inspeccione la empaquetadura Si está gastada o dañada sáquela y reemplácela Vea la Figura 6 2 Para sacar la tapa de la bomba del cilindro de la bomba retire los tornillos que aseguran la tapa de la bomba al tubo Vea la Figura 7 3 Inspeccione la junta tórica Si está gastada o dañada sáquela y reemplácela Lubrique la junta tórica con gel de petróleo Vea la Figura 8 4 Insp...

Страница 17: ...uelta 2 Manguera agrietada dilatada o defectuosa 1 Ajuste la tuerca de manguera 2 Reemplace el conjunto de cierre Atomizador difícil de bombear 1 La junta tórica del pistón No 2D o No 6C está dañada 2 La junta tórica del pistón No 2D o No 6C está seca 1 Reemplace la junta tórica del pistón come se describe en la sección Desensamblar y volver a ensamblar la bomba 2 Lubrique la junta tórica del pist...

Страница 18: ...2C 2E 2F 2G 1 1 1 2 1 3 2D KIT No 2 5B 5A 5C 5D 5F 5G 5H 4 5E 3 2 3 3 KIT No 5 9A 9F 10F 10B 10D KIT No 9 KIT No 10 7 21 7 18 11A KIT No 11 11G 11F 11E 11D 11B 9B 9E 9C 9D 11C 10E 10C 10A 8 1 8 3 8 2 11E 11F 11C 11D 11A 11B R O 7 SS 6A 6B 6C KIT 6 6C ...

Страница 19: ...SMITH PRO II 18 181843 ENSAMBLADO DE LA EXTENSIÓN DE 18 SMITH PRO II 21 181824 ENSAMBLADO DE LA EXTENSIÓN DE 21 SMITH PRO II SS 182112 ENSAMBLADO DE LA EXTENSIÓN DE 21 ACERO INOXIDABLE SMITH PRO II 1 181817 ENSAMBLADO DEL CIERRE SMITH PRO II 1 GALÓN 2 181818 ENSAMBLADO DEL CIERRE SMITH PRO II 2 GALONES 3 181819 ENSAMBLADO DEL CIERRE SMITH PRO II 3 GALONES KIT No 11 181910 JUEGO DE MANTENIMIENTO DE...

Страница 20: ...E ENCUENTRAN DISPONIBLES COMUNICÁNDOSE A The Fountainhead Group Inc Centro deservicio al cliente De lunes a viernes de 8 A M a 5 P M EST Llame sin costo al 1 800 311 9903 o Correo electrónico Info TheFGI com o Ingrese en línea a www TheFountainheadGroup com ...

Отзывы: