Copyright
©
2015
congatec
AG
PA3Cm11
64/81
Feature
Options
Description
Active Trip Point High
110 C
105 C
100 C
95 C
90 C
85 C
79 C
71 C
63 C
55 C
47 C
39 C
31 C
23 C
15 C
This value controls the temperature of the ACPI active Trip Point – the point in which the
operating system will enable the active cooling device at maximum capacity. DTS must
be enable on the CPU Submenu to make effective this Node.
Active Trip Point Low
110 C
105 C
100 C
95 C
90 C
85 C
79 C
71 C
63 C
55 C
47 C
39 C
31 C
23 C
15 C
This value controls the temperature of the ACPI active Trip Point – the point in which
the operating system will enable the active cooling device at half capacity. DTS must be
enable on the CPU Submenu to make effective this Node.