Forno Bravo
110
Ver. 2.0
©Forno Bravo, LLC 2016. All Rights Reserved.
43"
Cooking surface
10-1/2"
87"
25"
24"
Retain a minimum of 19-3/4"W x 19-3/4"H
opening required for air flow to
burner assembly
Cucina 100G Gas Modular Pizza
Oven Stand
Burner control unit
2" Floor insulation
2" Firebrick floor tiles
2" Dome wall
Allow 3" per side
for insulation
Allow for decorative facade
*(see chart)
62-1/2"
54-1/2" Plus 2" minimum
per side for facade
50"
39-1/2" Cooking
surface
Predrilled thermocouple
location
Burner unit
Decorative facade
Allow 1" Clearance all
the way around side walls
19"
39"
62-1/2" Plus 2" minimum
per side for facade
16"
26"
Minimum from hearth
Burner unit
1-5/8" hearth with 3/8" rebar
Allow for decorative facade
*(see chart)
Allow 3" for insulation
24" Stainless steel flue
with 8" interior,
anchor plate and rain cap
Shown with Forno Bravo Cucina 100G oven stand with non-combustible hearth
For more information: www.fornobravo.com
Installation guide: www.fornobravo.com/PDF/residential_install.
Top View
Decorative Facade Allowances
Depth
Width
Brick Arch
Usually 5"
N/A
Brick Landing
Usually 8"
Preference
Stucco
Approx 1"
N/A
Tile
Approx 1"
Approx 2"
Stone/Brick Veneer
Approx 1"
N/A
Brick or Masonary non veneer
Check Material Spec
N/A
UL737, UL2162, NSF-4, CAN/CGA-1.8 Dual,
ANSI-Z83.11 Dual, ANSI-Z21.58, CSA 1.6-2007 Listed
Made in the U.S.A.
Residential Gas Fired Pizza Oven
1
2
3
4
Revision
Sheet: of
6/13/2016
1
7
Front View
Side Elevation
SKU: FC2G100-SS-LP/NG
Architect Drawings
Gas Fired Pizza Oven w/ Stand
Casa2G 100G
Crate ships 58"W x 66"L x 49"H; Oven weight: 1835 lbs..
Wood, liquid gas or propane fuel;
Specifications:
Non-combustible hearth.
36" from front of oven landing to combustibles;
30" Side clearance from door opening;
14" above completed dome assembly;
1" clearance all the way around side walls;
Clearance to combustibles:
Refer to Gas Burner Drawing for air, & access requirements
Gas Requirements:
5
24" Stainless steel flue with 8" interior, rain cap and anchor plate comes standard
WARNING: READ ALL INSTRUCTIONS IN INSTALLATION MANUAL BEFORE INSTALLING AND USING APPLIANCE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.