Table of contents
3QLCLM
Edition: 04/2014
35
After mounting the complete power chuck system, check for imbalance and compensate any
remaining imbalance by screwing in corresponding threaded studs to DIN
914
•
on the cylinder side into thread d of the cylinder flange,
•
on the chuck side into the mounting flange
. The thread on the cylinder body of the actuating cylinder or on the body of the power chuck must not
be used for this purpose as the exact dynamic balancing of the actuating cylinder or power chuck will
be lost.
Check the proper mounting (using a dial gage) on the test faces of the power chuck.
The chuck body may be distorted if the chuck without
gripping jaws does not operate freely.
•
In that case, remove the chuck from the spindle of the machine.
•
and check the flatness of the chuck mounting flange and
•
the diameter of the taper register!
Radial run-out: max. 0.01 mm
(Guide value)
Axial run-out: max. 0.01 mm
(Guide value)