21
9. Web Control
USF-105S operation can be monitored by a web browser or SNMP Manager via a PC-network
connection. Power supply and fan states can be displayed by opening the USF-105S WebGUI from a
web browser. Control and monitoring of the modules (*1) installed in USF-105S can be done via
WebGUI. ALARM function assignments of the rear ALARM connector can be set via WebGUI. It is also
possible to monitor power supply, fan, temperature, modules (1*) through an SNMP manager.
(*1) Possible for the network support modules only. Refer to the operation manual of respective
modules.
9-1. Connecting USF-105S to a PC
Connect LAN 1 or LAN A connector to a PC via a hub.
LAN 1 and LAN A have different functions.
9-1-1. Connecting LAN 1 Port
The installed control modules are connected to the USF-105S internal switching hub. The LAN
1 port on the rear panel are also connected to the USF-105S internal switching hub. This
requires different IP addresses to be set for these ports and other devices in this network.
When a large amount of data is to be exchanged per module, use the LAN 1 port.
Factory settings
LAN1 IP Address: 192.168.0.10
Refer to LAN 1 settings of Sec. 10-3
. "Network Tab” for details on changing network settings.
Connection Example
LAN1
LED
Lit Green
: Connected
Flashing Orange:
Transmitting
and receiving data
USF-105S Rear panel
Web Browser
SNMP Manger