29
Trap Settings
Click
.
This window allows you to set various trap transmission from USF-105S to SNMP Manager.
Clicking
Refresh
allows you to update the window contents.
Unit Trap Settings
Item
Default
Settings
Description
Authentication
failure Trap
Disable
Disable
Enable
Enable
: If the community names set on Read
Only1, 2/ Read/Write1, 2 are different from
the community names set by SNMP
manager, a trap is sent.
PS Unit 1 Trap
Enable
Disable
Enable
Enable
: If Power Supply Unit 1 failure occurs,
a trap is sent.
DC Power 1
Trap
Enable
Disable
Enable
Enable
: If DC power supply failure occurs in
Power Supply Unit 1, a trap is sent.
PS Unit 2 Trap
Enable
Disable
Enable
Enable
: If Power Supply Unit 2 failure occurs,
a trap is sent.
DC Power 2
Trap
Enable
Disable
Enable
Enable
: If DC power supply failure occurs in
Power Supply Unit 2, a trap is sent.
FAN Trap
Enable
Disable
Enable
Enable
: When conditions of fan 1 to 4 are
changed, a trap is sent.
Slot Trap Settings
Item
Default
Settings
Description
Slot1 to 5 Trap
Disable
Disable
Enable
Enable
: If communications between Slot1 to
Slot5 with the control board are lost, a trap is
sent.