31
Transmitting Signal Name and Tally Data
The figure below shows an example signal name and tally data routing system using the
MFR-TALM.
Each serial port should be set as shown in the table below in the relevant page of the
MFR-TALM
Web-based Control accessed from "
http://192.168.1.62
" (default IP address)
on your web browser.
Serial Port Settings
Open the [MFR-TALM Web-based Control:
Port Settings
page] and perform port settings
under
Serial Port
.
As for the HVS-2000 unit, perform port setting in the [SETUP - SYSTEM - RS-422] menu.
Port
Menu
[Port Settings] - [Serial Port]
Connector
Function
Baud
rate
Parity
Web-based Control
[TALM Settings]
No. 1
HVS-TAL Protocol
Reception
38400
EVEN
Web-based Control
[TALM Settings]
No. 2
Router/HVS
connection Type 2
38400
NONE
HVS-2000
[SETUP - SYSTEM - RS-422]
No. 1
TALLY
38400
EVEN
HVS-2000
[SETUP - SYSTEM - RS-422]
No. 4
ROUTER
38400
NONE
Ethernet Hub (PC-LAN)
Ethernet Hub (MFR-LAN)
MFR-LAN
PC-LAN
RS-422(1)
RS-422(2)
MFR-6000
MFR-
9SDI12G
IN1
|
|
|
I
|
IN144
MFR-
9SDO12G
OUT1
|
|
|
|
|
OUT144
PC
MFR Web Control
MV Layout Editor
MFR-TALM
Video Switcher
(HVS-2000)
SERIAL
Multi Viewer
(MV-4200)
RS-422(1)
RS-422(4)
LAN
MFR-LAN
MFR-xxRU
PC-LAN
Rou
te
r t
a
lly
a
n
d
n
a
m
e
d
a
ta
Swit
c
h
e
r t
a
lly
d
a
ta
S
ig
n
a
l n
a
m
e
d
a
ta
T
a
lly
a
n
d
n
a
m
e
d
a
ta