2)
Power on the Slave MFR-6000. Set the IP addresses (5 and 6) as shown in the previous
page.
3)
Power on the Master MFR-6000.
4)
Open the Master MFR-6000 Web-based control and go to the
Build Settings
page.
Check on
Build Enable
to enable the Main Unit Link feature.
► See Sec. 11 "Main Unit Link" in the "Web-based Control Operation Manual."
3-3. Configuring the System with MFR-TALM
The block diagram below shows an example signal name and tally link system comprised of a
FOR-A video switcher and multiviewer using an MFR-TALM unit. The MFR-TALM is specifically
designed to perform the task of tally data computation, which is ordinarily undertaken by the MFR
main unit, to accelerate computation. RS-422 ports (1) to (4) are available for video switcher
connection.
VIDEO(SDI)
LAN (MFR-LAN)
LAN (PC LAN)
RS-422
PC-LAN
MFR-LAN(CPU1)
MFR-LAN(CPU2)
PC-LAN
RS-422(1)
RS-422(2)
SDI
s
ig
n
a
ls
SDI s
ig
n
a
ls
REF IN
MFR-6000
MFR-
9SDI12G
IN1
|
|
|
I
|
|
I
|
IN144
MFR-
9SDO12G
OUT1
|
|
|
I
|
I
|
|
OUT144
PC
MFR Web Control
MV Layout Editor
MFR-TALM
Video Switcher
(HVS-2000)
SERIAL
Multi Viewer
(MV-4200)
RS-422(1)
RS-422(4)
PGM
Monitor
PRV
Monitor
HDMI
HDMI
MV
Monitor
MV
Monitor
HDMI
MV
Monitor
HDMI
MV
Monitor
SDI
SDI
MFR-16RU
MFR-16RUD
MFR-40RU
MFR-18RU
MFR-39RU
Ethernet Hub (MFR-LAN)
Ethernet Hub (PC-LAN)
LAN
MFR-LAN
REF IN
BB
MFR-GPI