127
*2 When the FA-95CO is installed and Changeover is enabled the value will be displayed with
an asterisk, as
*SDI1,
*SDI2
, or
*COMPOSITE
indicating the input selection cannot be
changed. See section 5-7-1 “VIDEO INPUT SET” for details.
*3 Effective only if FA-95AIO option is installed.
NOTE
See section 14 “REMOTE” for details on pulse and level durations.
OUTPUT FUNCTION
Function
Description
NONE No
function
FREEZE
FREEZE ON:
Low
FREEZE OFF:
High (Open Collector)
VIDEO IN
Signal present:
Low
No signal present: High (Open Collector)
AUDIO IN
Signal present:
Low
No signal present: High (Open Collector)
REF IN
Signal present:
Low
No signal present: High (Open Collector)
FAN ALARM
*1
FAN failed:
Low
FAN normal:
High (Open Collector)
DC POWER 1
*2
Power 1 failure: Low
Power 1 normal: High (Open Collector)
DC POWER 2
*2
Power 2 failure: Low
Power 2 normal: High (Open Collector)
SDI1
SDI1 input signal is selected:
Low
SDI1 input signal is not selected:
High (Open Collector)
SDI2
SDI2 input signal is selected:
Low
SDI2 input signal is not selected:
High (Open Collector)
COMPOSITE
COMPOSITE input signal is selected:
Low
COMPOSITE input signal is not selected:
High (Open Collector)
YPbPr SMPTE
*3
YPbPr SMPTE input signal is selected:
Low
YPbPr SMPTE input signal is not selected:
High (Open Collector)
YPbPr BETACAM
*3
YPbPr BETACAM input signal is selected:
Low
YPbPr BETACAM input signal is not selected: High (Open Collector)
RGB
*3
RGB input signal is selected:
Low
RGB input signal is not selected:
High (Open Collector)
Y/C
*3
Y/C input signal is selected:
Low
Y/C input signal is not selected:
High (Open Collector)
CHANGEOVER
*4
CHANGEOVER inactive:
Low
CHANGEOVER occurring:
High (Open Collector)
CHGOV ENABLE
*4
CHNGEOVER is enabled:
Low
CHNGEOVER is disabled:
High (Open Collector)
CONV1 KEYER
CONVERTER1 KEYER is enabled:
Low
CONVERTER1 KEYER is disabled:
High (Open Collector)
CONV2 KEYER
CONVERTER2 KEYER is enabled:
Low
CONVERTER2 KEYER is disabled:
High (Open Collector)
*1 FAN ALARM goes to low (active), if either one of two fans fails.
*2 Effective if the optional FA-95PS is installed.
*3 Effective if the optional FA-95AIO is installed.
*4 Effective if the optional FA-95CO is installed.