95
5-18-2. CONV2 VI OUT
Displays whether the RP186 VI ancillary data is inserted into CONV 2 output video signal.
When no RP186 VI is in the CONV2 output video signal
C O N V 2 V I O U T
6 8 3
R P 1 8 6 V I : A B S E N T
When RP186 VI is in the CONV2 output video signal
C O N V 2 V I O U T
6 8 3
R P 1 8 6 V I : P R E S E N T
A F D : 0 2 S S : 0 2
B O X 1 6 : 9 T O P
D 1 : 1 2 D 2 : 0 2 D 3 : 0 2
Displays the status of RP186 VI (Video Index) Class1.
AFD: Active Format Description is displayed in hexadecimal format.
SS: Scanning System is displayed in hexadecimal format.
The detected AFD type is shown on the third row.
D1-D3: Detected Data are displayed in hexadecimal format.
See section 20-6 “AFD Code Abbreviations” for details on AFD types.
5-18-3. CONV2 WSS OUT
Displays whether the BT1119 WSS ancillary data is inserted into CONV 1 output video signal.
When no BT1119 WSS is in the CONV2 output video signal
C O N V 2 W S S O U T
6 8 4
B T 1 1 1 9 W S S : A B S E N T
If ANC MODE in 5-10-10 CONV2 ANC SET is set to H/V ANC, the state of the V ANC setting
(PASS or BLANK) is displayed.
When BT1119 WSS is in the CONV2 output video signal
C O N V 2 W S S O U T
6 8 4
B T 1 1 1 9 W S S
:
P R E S E N T
A F D : 0 4
B O X 1 6 : 9 T O P
B I T 1 3 - 0 : 0 0 0 4
Displays the status of BT1119-2 WSS (Wide Screen Signalling).
AFD: Active Format Description is displayed in hexadecimal format.
The detected AFD type is shown on the third row.
BIT13-0: Detected Bits 13 – 0 are displayed in hexadecimal format.
See section 20-6 “AFD Code Abbreviations” for details on AFD types.