126
*3 Details of the output functions are shown in the “
◆
OUTPUT FUNCTION” on the next page.
Power 1 and 2 are selectable if the FA-95PS option is installed.
*4 Effective if the FA-95CO option is installed.
*5 Effective if the FA-95AIO option is installed.
*6 CONV1 LOGOs 1 - 7, and CONV2 LOGOs 1 – 7 will be displayed, if selected, as “LOGO
ID: 1”. Logo ID can be assigned to any number 1 through 256. In the following cases, the
logo will not be inserted to the converter output signals, although data will be loaded to the
FA-9500.
- No logo is registered under the selected Logo ID.
- The registered logo format and converter output video format do not match.
- The keyer of the relevant converter is turned off.
INPUT FUNCTION
Function
Mode
Description
NONE
No
function
BY-PASS Level
Selects OPERATE or BY-PASS
Shorted to GND: BY-PASS
OPEN: OPERATE
FREEZE
*1
Level
Sets FREEZE ON/OFF
Shorted to GND: FREEZE ON
OPEN:
FREEZE
OFF
FULL CB
Level
Selects FULL CB (color bar) for the test signal
Shorted to GND: FULL CB ON
OPEN:
FULL
CB
OFF
75% CB
Level
Selects 75% CB for the test signal
Shorted to GND: 75% CB ON
OPEN:
75% CB OFF
SMPTE CB
Level
Selects SMPTE CB for the test signal
Shorted to GND: SMPTE CB ON
OPEN:
SMPTE CB OFF
RAMP Level
Selects RAMP for the test signal
Shorted to GND: RAMP ON
OPEN:
RAMP
OFF
SDI1
*2
SDI2
*2
COMPOSITE
YPbPr SMPTE
*3
YPbPr BETACAM
*3
RGB
*3
Y/C
*3
Pulse
Selects an input video signal. Switches over to the
selected input signal when shorted to GND.
CHGOV ENABLE
CHGOV DISABLE
Pulse
Enables or disables the CHANGEOVER settings.
If CHGOV ENABLE is selected, CHANGEOVER will be
enabled when the pin is shorted to GND.
If CHGOV DISABLE is selected, CHANGEOVER will be
disabled when the pin is shorted to GND.
However, CHANGEOVER may not be enabled
depending on the 5-7-1 VIDEO INPUT SET menu
setting.
DEFAULT
EVENT 1 - 100
Pulse
Loads the DEFAULT, and events 1 through 100.
When shorted to GND, the assigned settings (among
default and events) will be loaded.
CONV1 KEYER
CONV2 KEYER
Level
Sets the converter 1 keyer ON/OFF.
Shorted to GND: Keyer ON
OPEN:
Keyer
OFF
CONV1 LOAD 1-7
CONV2 LOAD 1-7
Pulse
The logo assigned to a LOGO ID will be loaded to the
selected converter.
CONV1/2 LOAD 1 - LOAD 7 are assigned to LOGO IDs.
*1 Although FREEZE is set to ON, the freeze function is disabled if SYNCHRO in section
5-10-1 “FS MODE SET” is set to LINE, AVDL, or INPUT. In such case, the menu will be
displayed as “
*
FREEZE”. To enable FREEZE for INPUT FUNCTION, be sure to set
SYNCHRO to FRAME.
Содержание FA-10DCCRU
Страница 15: ...xv 25 2 External Dimensions 276 Index 277 ...
Страница 16: ......
Страница 248: ...232 10 Systen Block Diagram Audio ...
Страница 298: ......