background image

GB

User Manual

Thank you for choosing a Fontastic

®

 Product. 

Please read this User Manual carefully and comply with 

the safety instructions.

Package content

Thermostatic radiator valve | 2x AA batteries | 4x adapters | Manual

Only included in the kit: Gateway | Micro-USB power supply | Micro-USB cable

Overview

1. 

AUTO/MANU button

2. 

Plus button

3. 

PROG button

4. 

Temperature sensor

5. 

Minus button

6. 

Temperature button

7. 

Battery compartment

8. 

Union nut

9. 

Danfoss (RA) adapter

10. 

Danfoss (RAV) a long plunger

11. 

Caleffi adapter

12. 

Giacomini a short plunger

13. 

LED display

14. 

Micro-USB connector

15. 

Mode button

Product description

The thermostatic radiator valve (TRV) that controls your radiator can be easily 

installed on ordinary radiators. The TRV can be controlled and programmed 

directly from the device itself or via the FontaHome app in conjunction with the 

WiFi gateway.

Installing the TRV

The TRV is suitable for all common valves.

1. 

Remove the old thermostat from the radiator If necessary, set the thermostat to

    the highest setting to facilitate removal.

2. 

Determine the type of valve and fit an adapter if necessary.

• 

Most common valves with thread dimensions of 

M30x1.5

 do not require an

  additional adapter.

• 

For 

Danfoss

 valves series 

RA

, please screw the adapter 

(9)

 to the valve body.

• 

For 

Danfoss

 valves series 

RAV

, please screw the adapter 

(10)

 to the valve body

  and place the long plunger on the valve.

• 

For 

Caleffi

 valves, place the adapter 

(11)

 on the valve body.

• 

For 

Giacomini

 valves, screw the adapter 

(12)

 to the valve body and place the

  short plunger on the valve.

3. 

Open the battery compartment 

(7)

 located at the bottom of the TRV and insert

    two new AA batteries of the same type into the body and close the battery

    compartment. Make sure the polarity is correct. This is indicated by the marking

    in the battery compartment.

4. 

Once the batteries are inserted into the battery compartment, the TRV will

    switch on and perform a self-test. The valve retracts and the display shows

    „

test

“.

5. 

Screw the new thermostat onto the valve body by hand in a clockwise direction.

6. 

After one minute or after pressing any key, the TRV will be calibrated with the

    valve and the display shows „

rESE

“.

Note: 

If a radiator is not compatible, ask your dealer for a suitable 

M30x1.5

 

adapter for the TRV.

Note: 

Use only new non-rechargeable alkaline or lithium batteries. The batteries 

must be replaced when the battery symbol appears on the display.

Note: 

Do not use a pipe wrench when installing the new thermostat. Attach it by 

hand only.

Date/time setting

After the TRV has been calibrated, the date and time can be set:

First set the year, then the month, day and time. Use the 

plus/minus buttons

 to 

scroll and the 

temperature key (6)

 to change between year, month, day, hour and 

minute. To save, press the 

AUTO/MANU button (1)

.

Note: 

After 

20 seconds

 the date/time setting will not be saved. To reset, press 

and hold the 

PROG button (3)

 for about 

6 seconds

.

Note: Date and time can also be set automatically in connection with the WiFi 

gateway.  To activate/deactivate the function, press and hold the 

PROG (3) and 

temperature (6) buttons

 simultaneously for about 

6 seconds

. Use the 

PROG 

button (3)

 to switch between 

ON

 and 

OFF

 and confirm by pressing the 

AUTO/

MANU button (1)

.

Note: 

If you do not use the automatic date/time setting, the date/time must be set 

again when replacing the batteries.

Program setting

The TRV has a program memory for one week with 4 time segments (morning, 

noon, evening, night). To activate it, proceed as follows:

1. 

Press the 

PROG key (3) 

to call up the program setting.

2. 

Use the 

plus/minus buttons

 to select whether a setting should be used for all

    days of a week (display shows 1-7) or each day of the week should be pro-

    grammed individually (display shows 1/2/3/4/5/6/7).

3. 

As soon as you have selected the mode, press the 

PROG button (3)

 to switch

    between time, temperature and day for the segment. You can change the

    values with the 

plus/minus buttons

.

4. 

To save the setting, press the 

AUTO/MANU button (1)

.

5. 

The target temperature for the current time segment is shown in the display.

Note: 

Use the 

temperature button (6)

 to quickly return to the weekday setting.

Note: 

To reset the program memory, press and hold the 

plus/minus buttons

 for 

approx. 

6 seconds

 until „

def

“ appears in the display.

Note: 

You can briefly overwrite the target temperature of the current time segment 

using the plus/minus keys. Press the 

AUTO/MANU button (1)

 twice to return to 

the stored temperature.

Switching between program/manual mode

By pressing the 

AUTO/MANU button (1)

, you can choose between program 

(AUTO)

 and manual temperature setting 

(MANU)

.

Absence mode

The TRV has an absence mode that you can activate via the app, which sets the 

target temperature to 

16°C

 to save energy when you are not at home. The mode 

is active when the display shows „

LEAV

“.

Display of the ambient temperature

Press and hold the 

temperature button (6)

 for about 

6 seconds

 to display the 

current ambient temperature.

Child lock

To protect the TRV from unintentional adjustments, it is equipped with a child lock.

To activate/deactivate, press and hold the 

AUTO/MANU (1) and PROG (3) 

button

 for about 

6 seconds

. The TRV is locked as soon as „

bloc

“ appears in the 

display.

Limescale protection

If the TRV is not used within 2 weeks, the valve opens and closes once to prevent 

limescale inside the valve, „

AdAp

“ appears in the display.

Open window detection

If a window is opened near the TRV and the temperature drops rapidly, the TRV 

automatically closes the valve to save energy and the display shows „

OPEN

“. 

You can cancel this by pressing any key. As soon as the temperature increases or 

after about 

45 minutes

, the TRV returns the valve to its previous position.

Frost protection

Press the 

temperature button (6)

 to activate the frost protection. The valve is 

closing.

When ambiant temperature drops below 

6°C

 the TRV opens and above 

8°C

 the it 

closes the valve to protect the radiator against frost.

Connection with the FontaHome App

The wireless thermostat can be used in conjunction with the Fontastic WiFi gate-

way (model SH15) via the FontaHome app. To use the gateway and TRV with the 

app, you must have the FontaHome app installed on one of your devices such 

as a smartphone or tablet. With the app, you can add FontaHome devices and 

control them worldwide.

App installation

Get the „FontaHome“ app from Google Play, the App Store,

follow the QR code or at 

www.d-parts.de/privacy_fontahome

.

Registration

You must register before using the FontaHome app. You can choose from various 

registration options.

Note: 

It is technically not possible to use the app without registration. Please 

note the privacy policy for the processing of your personal data in the app or at 

d-parts.de/privacy_fontahome

.

Adding the gateway (simple mode)

1. 

Open the „

FontaHome“

 app on your smartphone, log in and select

    „

Add device

“ or the „

+

“ symbol in the upper right corner.

2. 

Select „

Add

“.

3. 

Connect the gateway to a USB power supply using the micro-USB power

    adapter or micro-USB cable. The gateways LED indicator will initially light up

    blue and red and will flash red when the gateway is ready to connect. 

4. 

Please make sure that the LED display of the gateway is blinking quickly

    (approx. 2 times/second) as shown in the app. If the LED does not flash as

    described, press and hold the back button of the gateway for about 6 seconds.

5. 

Press „Next step“ in the app and allow the device to connect to the WiFi

    network connected to your smartphone by entering the WiFI password.

Radiator Valve

3.

6.

1.

2.

4.

5.

7.

8.

9.

10.

11.

12.

13.