Instructions for the installer
38
3.12 Installation and operation with Open Therm Remote Control (optional)
WARNING
Only use original Remote Control Units supplied by the manufacturer.
The correct operation of the Remote Control itself and of the boiler is not guaranteed if non original Remote Control units
not supplied by the manufacturer are used.
The boiler may be connected to an Open Therm Remote Control (non-compulsory optional accessory supplied by manufacturer).
The Remote Control must only be installed by qualified personnel.
To install the Remote Control, refer to the instructions provided with the Remote Control itself.
The Remote Control must be installed on an indoor wall at a height of approximately 1.5 m from the floor and in a suitable location
for measuring ambient temperature: do not install in recess or corners, behind doors or curtains, and install away from heat sources,
direct sunlight, air draughts and water sprays.
The Remote Control cables must be connected to terminals 3 and 4 of the electronic board.
The Remote Control connector is protected against inverted polarity, and the connections may be inverted.
WARNING
Do not connect the remote control to mains electrical power 230 V ~ 50 Hz.
The remote control wiring must not be grouped together in the same sheath as the power cables: if the cables are shea-
thed together, electrical interference from the power cables may compromise the functions of the Remote Control;
For complete instructions on how to program the Remote Control, refer to the instruction manual included in the Remote Control kit.
Board and Remote Control communicate in each operating mode: OFF, SUMMER, WINTER, CH ONLY.
Boiler display layout corresponds to the setting made from the Remote Control, as for the operating mode.
The remote control may be used to view and set a number of special parameters denominated
TSP
parameters and reserved solely
for qualified technicians.
Setting the
TSP0
parameter sets the default data table and reloads all original data, cancelling any modifications previously made to
individual parameters.
If a single parameter is found to be incorrect, the value given in the default value table is restored.
If the user attempts to set a value not within the permissible range for the parameter, the new value is rejected and the existing value
is maintained.