Type C32
• Minimum permissible length for vertical coaxial pipes is 1 metre, equal to the length of the chimney.
• Maximum permissible length for vertical coaxial pipes is 11 metres, including the chimney.
•
For each additional 90° elbow, maximum permissible length is to be reduced by 3 meters.
•
For each additional 45° elbow, maximum permissible length is to be reduced by 0.5 meter.
Use the diaphragms supplied with the boiler.
Pipe length (m)
Flue gas venting diaphragm diameter
1 < L ≤ 5
Ø 39
5 < L ≤ 6
Ø 39.8
6 < L ≤ 7
Ø 42
7 < L ≤ 9
Ø 44
9 < L ≤ 10
Ø 47
10 < L ≤ 11
Ø 49
Tab. 9 Table indicating coaxial pipes 125/80 C32 type
WARNING
The pipe length information refers to air intake/flue gas venting ducts made from smooth, rigid pipes approved and sup
-
plied by the manufacturer.
The illustrations are indicative only. When installing accessories, refer to the instructions supplied with the accessories themselves.
B
C
A
B
L
Fig. 10 0KITCONC00 (100/60 mm)
134
250
10
0
70
0
400
Fig. 11 Dimensions for coaxial pipe
A.
Diaphragm
B.
Neoprene gasket
C.
Blanking cap
L
= from 1 m to 6 m