Technical features and dimensions
22
2.4 Operating data
Burner pressures reported in the following page must be verified after the boiler has been operating for 3 minutes.
Fuel
Gas mains pressure [mbar]
Nozzle [mm]
Pressure at the burner
[mbar]
Natural gas G20
20
1,35
3,0
Natural gas G20
13
1,35
3,0
Butane gas G30
29
0,80
6,8
Propane Gas G31
37
0,80
8,6
Tab. 1 **non tradotto**
Fuel
Gas mains pressure [mbar]
Nozzle [mm]
Pressure at the burner
[mbar]
Natural gas G20
20
1,27
3,2
Natural gas G20
13
1,27
3,2
Butane gas G30
29
0,77
7,2
Propane Gas G31
37
0,77
9,2
Tab. 2 **non tradotto**
2.5 General characteristics
Description
um
CTFS 13 AF
CTN 13 AF
Appliance category
-
II2H3+
Burner nozzles
no.
11
11
Nominal heat input
kW
12,5
12,0
Heat output
kW
11,0
10,5
Minimum CH system pressure
bar
0,5
0,5
Maximum CH system pressure
bar
3,0
3,0
DHW circuit min. pressure
bar
0,5
0,5
DHW circuit max. pressure
bar
8,0
8,0
DHW specific flow rate (Δt=30K)
l/min
11,1
10,3
Electric power supply – voltage / frequency
V - Hz
230 - 50
Power mains supply fuse
A
3,15
3,15
Maximum power consumption
W
120
88
Pump absorption
W
84
84
Electric protection rating
IP
X4D
X4D
Net weight
kg
25,16
22,74
Natural gas consumption (*)
cu. m/h
1,32
1,27
Butane gas consumption
kg/h
0,99
0,95
Propane gas consumption
kg/h
0,97
0,93
Maximum CH working temperature
°C
83
83
Maximum DHW working temperature
°C
58
58
Total capacity of expansion vessel
l
7
7
Maximum recommended system capacity (**)
l
100
100
Tab. 3 General specifications
(*) Value referred to 15 °C - 1013 mbar
(**) Maximum water temperature 83°C, expansion vessel pressure 1 bar