Instructions for the installer
34
The illustrations are indicative only. When installing accessories, refer to the instructions supplied with the accessories themselves.
Configurations for 80 mm split air intake/flue gas venting pipes.
A
B
(supplied with
the boiler)
Fig. 12 0SDOPPIA13
250
400
70
0
134
74
Ø 80
199
108
Fig. 13 Dimensions for split pipes
H ≥ 150 mm
500 mm
2
1
Fig. 14 Air intake and flue gas venting examples
135 mm
≥ 250 mm
45 mm
500 mm
500 mm
3
Fig. 15 Air intake and flue gas venting example
Example 1
. . . . .
Primary air intake and flue gas venting via two opposite external perimeter walls.
Example 2
. . . . .
Primary air intake via perimeter wall and flue gas vent on roof.
Example 3
. . . . .
Primary air intake via perimeter wall and flue gas vent via same external perimeter wall.
Installation type: C62
•
Maximum chimney residual head (intake-venting): 105 Pa.
•
Avoid condensate build-up inside the equipment.
•
Maximum flue gas recirculation: 10%.