Technical features and dimensions
17
2.1.3 Operating features
•
Electronic flame modulation in CH mode, with timed rising ramp.
•
Electronic flame modulation in DHW mode.
•
Flow freeze protection function: ON 5°C; OFF 30°C or after 15 minutes of operation if CH temperature > 5 °C.
•
CH Maximum heat input parameter adjustment.
•
Ignition heat input adjustment parameter.
•
Ignition flame propagation function.
•
CH thermostat timer: 240 seconds (adjustable).
•
Heating pump post-circulation function in CH, freeze protection and flue cleaning modes: 30 seconds (adjustable).
•
Pump post-circulation function in DHW: 6 seconds in winter mode, 1 second in summer mode.
•
Post-ventilation function after working: 10 seconds (CTFS).
•
Post-ventilation function for heating temperature > 95°C (CTFS).
•
Circulation pump and deviating valve anti shut-down function: 30 seconds of operation after 24 hours of inactivity.
•
Ready for connection to an ambient thermostat.
•
Ready for operation with an OpenTherm remote control (optional, supplied by the manufacturer).
•
Anti-water hammer function: can be set from 0 to 3 seconds.
• DHW function priority.