110CT/CR/FB Ice and Water Dispensers
11
8. Connect molded drain tube to evaporator drain pan, purge solenoid and rear drain fitting.
CLEANING CUP
WATER SUPPLY
3/8" FPT, 45-90 F (7-32 C)
10-70 PSI (69-483 KPA)
RESERVOIR FILL
SOLENOID
WATER
RESERVOIR
EV
APORA
TOR
ICE
NOZZLE
DRAIN PAN
VENT
TO DRAIN CUP
9. Connect ice machine bin signal cable to two-pin receptacle on the dispenser electrical box.
ICE MACHINE
Note: Do not apply
power to ice machine
bin signal connection!
Ice machine can only
see contact closure.
1
2
DISPENSER
10. On dispensers equipped with water-cooled ice machines, connect condenser water supply and drain
lines to condenser fittings on ice machine.
11. Turn on water supply and check for leaks.
12. Plug dispenser power cord into 15A rated NEMA 5-15 circuit.
13. If dispenser is equipped with SensorSAFE, remove protective plastic coating from dispense sensor
labels.
14. Turn on power and bin signal rocker switches and test operation.
15. Sanitize ice machine following instructions in ice machine manual.
16. Remove dispenser hopper access lid and sanitize dispenser according to instructions on page 12.
17. Replace front cover and secure with screws. Installation is complete.
ice level control thermostat
0.75" (19 mm)
Hand bend cap tube
end to approximately
45° as shown
45°