110CT/CR/FB Ice and Water Dispensers
Specifications
Electrical
§
Models with RIDE ice machines (110CR425A/W). Ice machine and dispenser require their own separate,
dedicated circuit.
Dispenser with
ice machine
Max.
circuit
Dispenser without
ice machine
Max.
circuit
Basic electrical: 115 V/60 Hz/1 phase
11.0A
20A
4.0A
20A
§
Freestanding models (110FB425A/W, 110CT425A/W) require a dedicated circuit.
Total system
Max. circuit
Basic electrical: 115 V/60 Hz/1 phase
11.0A
20A
§
Dispensers and RIDE ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug.
Connect to a dedicated 15A circuit.
CAUTION!
All field wiring must be installed in accordance with NEC and local electrical codes. Field wiring diagram is
intended only to aid electrician or technician in understanding how equipment works.
Model
Electrical connection
Circuits required
110FB425A/W
cord & plug provided
115/60/1, 15A max. fuse size
110CT425A/W
cord & plug provided
115/60/1, 15A max. fuse size
110CR425A/W
cord & plug provided
115/60/1
Dispenser: 15A max. fuse size,
Ice machine: 15A max. fuse size
Ambient
Air temp*
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp
†
90 F/32 C Max.
45 F/7.2 C Min. (Best performance below 70 F/21 C)
Water pressure
70 P.S.I./5Bar Max.
10 P.S.I./0.7 Bar Min.
*
Ambient air temperature is measured at the air-cooled condenser coil inlet.
†
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
110CR with RIDE ice
machine
110CT with integral
ice machine
110FB with ice
machine in base
Dispenser drain
3/4" MPT
3/4" MPT
3/4" MPT
Ice machine drain
3/4" MPT
3/4 MPT
3/4" MPT
Dispenser water inlet
3/8" FPT
3/8" FPT
3/8" FPT
Ice machine water inlet
—
3/8" FPT
—
RIDE IM water inlet
3/8" FPT
—
—
Cond. inlet – w/c only
3/8" FPT
3/8" FPT
3/8" FPT
Cond. drain – w/c only
3/8" FPT
3/8" FPT
3/8" FPT
Note: Water shut-off recommended within 10 ft (3 m) of dispenser. Drain to be hard-piped and insulated.
Maintain at least 1/4" per foot (20 mm per 1 m) run of slope.