26 Service
00981795R03 – FZR20/25 LB, PL
Fig. 63
2. Use
to scroll and highlight
Refrigeration Controls (Fig. 63).
Fig. 64
3. Press and hold Enter and together for 3 seconds (Fig. 64).
Fig. 65
4. Use
to scroll and highlight
Door Heater Cycle and press Enter
to select (Fig. 65).
Fig. 66
5. Heater ON cycle is shown as a percentage of 20 minute cycle (Fig. 66).
6. Use
to adjust heater ON cycle percentage and press
Enter to
select. Do not go lower than default setting of 75%.
7. Press Back until the main temperature display screen is displayed.
Refrigeration Controls
Password on/off
PIN
Set Time/Date
-30.0C
Back Enter
Calibration
Refrig Setpoint
Differential
High Setpoint Limit
-30.0C
Back Enter
Low Set Point Limit
Door Heater Cycle
Upload To Hotkey
Download from Hotkey
-30.0C
Back Enter
Heater On Percent
-30.0C
Back Enter
75