22 Cleaning
00981795R03 – FZR20/25 LB, PL
Annual cleaning and inspection
Fig. 54
Removal of dust and other particulates from air intake areas and the
condenser is important for proper operation. Environments with large
amounts of dust may require more frequent cleaning.
1. Disconnect power to unit by turning power switch off (located on upper
front facade panel) and removing power cord from receptacle.
2. The condenser can be accessed from top for cleaning. The side panel
in front of condenser may be completely removed for easier cleaning
by disconnecting facade and removing upper side panel. See “Facade
removal” on page 30 for facade removal instructions.
3. Inspect condensate pan for any debris or obstruction in condensate
pan (Fig. 54.1).
4. Use a vacuum cleaner with brush attachment to clean condenser,
compressor and related parts.
5. Use a flashlight to look in louvers on the top return air panel (Fig. 55.1).
6. If there is significant ice accumulation in the return, defrost completely.
7. Door maintenance: Place a dab of white lithium grease on top of hold
open arm and keeper on lower hinge assembly of door (Fig. 56.1).