Manual stop 

Any additional command on the smart key while in motion, pressing STOP on the optional remote 

control or undocking the smart key stops the lift immediately. Stopping is done with no time delay 

whereas a drive command starts with a preprogrammed time ramp for a smooth operation. 

 

Automatic stop  

Upon reaching the programmed end position in open direction, the lift stops with a time ramp in 

order to prevent cover teeter.  

The foldaway lift system moves the cover within approx. 30 sec into the programmed end position. 

While the motors run the illumination of the dock changes to yellow. The foldaway controller 

continuously monitors 

-

lift load (total cover weight) 

-

temperature of the power stage 

-

cover position 

-

synchronism of the lift arms 

-

motor currents 

Each cover position is associated with a reasonable load programmed in the micro controllers 

memory. Exceeding such a load stops the lift and/or triggers a visible alarm on the docking panel. 

The lift will not travel beyond programmed limits independent of commanded direction.  

Cover Lifetime 

The cover lifetime monitor is a program routine that estimates the quality of thermal insulation of 

the cover by measuring it´s gain in weight with time. 

A water soaked cover has reduced ability to protect from cold environment and gains in weight.  

A water soaked cover can vary in weight over time depending on the environmental conditions.  

The docking light will illuminate in blue blinking whenever the micro controller senses heavy loads 

while in motion that do not exceed the shutdown limit.  

A blue blinking illumination is considered normal when: 

-

the vinyl of the insulation cover sticks to the spa shell while opening 

-

the cover is contaminated e.g. thin layer of snow 

 

The lift control logic can not differentiate between a water soaked cover and cover 

contamination.  

Ignoring the blue blinking signal for a longer period may end in a lift shutdown situation. 

Lock the spa cover lift system 

Take off the smart key after the system has come to a full stop 

including the reverse sequence of the drives

. The green 

illumination will change to white. The spa cover lift is now 

locked.

13

Содержание F1-230 V10

Страница 1: ...er lift system operating manual V 1 5 Model F1 230 V10 European version www foldaway at Document Number BEB 203 214 9 Before first use of the appliance please read these Operating Instructions and act...

Страница 2: ...has been declared as a whole including the product that is subject of this declaration in conformity with legal requirements Above declarations apply to the original product only Any modification s to...

Страница 3: ...Illustration A Illustration B 3 1 4 2 3 5 6 7 11 8 9 10 12 13...

Страница 4: ...ustration D EMERGENCY LIFT OPERATION 1 REMOVE THE PLASTIC SECURING CLIP FROM THE COVER DOWEL ON BOTH SIDES 2 DETACH THE LIFT CARRIAGE MECHANISM FROM THE COVER ON BOTH SIDES 3 MANIPULATE AND SECURE THE...

Страница 5: ...docking system 10 Cover quick release mechanism 10 Self locking drives 10 Overload protection 10 Safety controller 11 Danger areas 11 Daily Operation 12 Getting started unlock the system 12 Open the s...

Страница 6: ...ments or suggestions are welcome to BEB Fertigungscenter GmbH Co KG A 2433 Margarethen am Moos B ckerstrasse 1 Austria Phone 43 0 2230 20270 130 support foldaway at Disclaimer The information containe...

Страница 7: ...The packaging material can be recycled Please do not place the packaging into the ordinary refuse for disposal instead arrange for the proper recycling Old lifts contain valuable materials that can b...

Страница 8: ...anical release circlip on both lift arms Make sure the area below the cover is free before pulling the circlips Removing the clips exposes the spa cover to free fall Be careful when touching dark surf...

Страница 9: ...chieved by adjusting actuator speed during drive If the adjustment can not compensate the unbalance between the actuators both motors stop The logic board monitors current limits position sensor data...

Страница 10: ...y depending on the current position after releasing both sides Self locking drive The drives are self locking in any position even without power supply Overload protection Each drive is equipped with...

Страница 11: ...riodic self test the safety circuit continuously monitors the function of all relevant internal parts to ensure a safe operation Danger areas The foldaway lift system is able to detect certain objects...

Страница 12: ...our foldaway smartphone app Make sure by visible contact that the movement area of the lift and the parking area of the spa cover is free Parts of the vinyl cover can stick to the spa surface An indic...

Страница 13: ...t travel beyond programmed limits independent of commanded direction Cover Lifetime The cover lifetime monitor is a program routine that estimates the quality of thermal insulation of the cover by mea...

Страница 14: ...tings allow water to infiltrate the structure In freezing outside conditions the transparent coating can chip off upon freezing of water underneath Avoid acid and caustic solutions on the carbon coati...

Страница 15: ...utilization If the failure is consistent consult your customer service A red continuous illumination indicates a failure in the safety relay Please consult an authorized customer service Close the sp...

Страница 16: ...l position One long beep confirms the action The LED illumination is changing to green blinking for approximately 4 seconds While in progress the LED illuminates blue The alignment is finished when th...

Страница 17: ...15mm approx 1 2 inch at the tip of the arm If the distance is greater unscrew the black drive cap Check the tightness of center allen screw If the screw is loose move the arm manually forward and bac...

Страница 18: ...will automatically align the lift system ________________________________________________________________________ Q My spa cover lift is working in closing direction only I cannot open the spa A The p...

Страница 19: ...60Hz 150VA internal fuse 6 3A 20x5 power stage max temp 120 C drive modulation and frequency PWM 16kHz ultra low noise ambient temp Ta 20 C bis 60 C standby power 15mA CE rating EMV industrial environ...

Страница 20: ...BEB Fertigungscenter GmbH Co KG B ckerstra e 1 2433 Margarethen am Moos Austria Phone 43 2230 20 270 130 Fax 43 2230 20 270 900 email support foldaway at 20...

Страница 21: ...linking position data fault alignment required 180 AND within 2sec 180 green blinking system message alignment imminent blue system message obstacle detected alignment in progress internal fault clear...

Отзывы: