18
DLI-130/230 ANA – analogue connection variant
(1) Analogue Input 1
Analogue audio signals can be fed in via these 3-pin Phoenix connectors.
One of the two 3-pin Phoenix connectors can be used as a link!
(2) Analogue Input 2
Analogue audio signals can be fed in via these 3-pin Phoenix connectors.
One of the two 3-pin Phoenix connectors can be used as a link!
(3) Fault message contact (2x)
An error status can be reported via these open/closed contacts. The fault contact relay (2 x UM)
should be operated with a maximum of 50 V and 500 mA.
One of the two 3-pin Phoenix connectors can be used as a link!
(4) FOHHN-NET Input (2x)
The
DLI-130/230 AES
can be connected to the
FOHHN-NET
remote control network via these 3-pin
Phoenix connectors
One of the two 3-pin Phoenix connectors can be used as a link!