3.1.5 Terminate VGA (Toggle)
This control connects the TView Pro AV1600's 75 Ohm termination resistors onto the computer's RGB output lines.
Select “TERMINATED” unless you are using the TView Pro AV 1600 with a pass through monitor cable (such as a
HyperCable-PC, intended for use with the Pro AV CP product line).
3.1.6 Fine Genlock H Position (Range) (Not available from IR remote mouse)
This control adjusts the relative horizontal picture position of the Television Output with respect to a Reference
Television signal. This control is only operational when using the Genlock capability of the TView Pro AV 1600.
3.1.7 Coarse Genlock H Position (Range) (Not available from IR remote mouse)
This control adjusts the relative horizontal picture position of the Television Output with respect to a Reference
Television signal. This control is only operational when using the Genlock capability of the TView Pro AV 1600.
3.1.8 Genlock Subcarrier Phase (Range) (Not available from IR remote mouse)
This control adjusts the relative Subcarrier Phase of the Television Output with respect to a Reference Television
signal. This control provides slightly more than 180 degrees of variable phase control and most be used in
conjunction with the Genlock Subcarrier Phase Reverse Control to establish 360 degrees of phase control. This
control is only operational when using the Genlock capability of the TView Pro AV 1600.
3.1.9 Genlock Subcarrier Phase Reverse (Toggle) (Not available from IR remote
mouse)
This control selects 180 degrees of Television Output Subcarrier Phase shift with respect to a Reference Television
signal. This control is only operational when using the Genlock capability of the TView Pro AV 1600.
3.1.10 Genlock Termination (Toggle) (Not available from IR remote mouse)
This control applies a 75 Ohm termination to the Genlock input. This control is always operational.
3.1.11 NTSC/PAL (Toggle) (Not available from IR remote mouse)
This control selects between PAL and NTSC operation. Set this control to PAL for European operation. Set this
control to NTSC for American operation.
3.1.12 Flicker Reduction Filter (Multiple)
This control operates the Flicker Reduction Filter. Flicker filter settings from 0 (Flicker Filter is Off) to 7 (Flicker Filter
is at a maximum) are available. The display will indicate “FLK FLT = #” where # is the current setting of the Flicker
Filter.
3.1.13 Brightness Boost (Toggle) (Not available from IR remote mouse)
This control applies a Brightness Boost to the Television Output. Set “BRIGHT MAX” to raise the brightness of the
Television Output. Set “BRIGHT NORM” to set the Television Output to regulation brightness level.
3.1.14 Freeze Frame (Toggle)
This control freezes the output video of the TView Pro AV. Select “INPUT FROZEN” to freeze the picture. Select